Transformer types and project fit

Power Transformers for Sale and Project Supply

J&J Transformers LLC is a power transformer supplier serving utilities, data centers, EPCs and industrial projects nationwide. Browse GSU, substation, step-down and pad-mounted transformers by voltage and capacity. Need another configuration? Send Tommy Marco your kVA or MVA, voltages, quantity and required date. Each offered unit requires engineering review and written availability confirmation; subject to prior sale.

J&J Transformers LLC · Sugar Land, Texas · Serving projects nationwide

Tommy Marco · tommy@jjtransformers.com

Product classes
GSU · substation · pad-mounted
Voltage classes
69 · 115 · 138 · 161 · 230 · 345 kV
Availability
Written reconfirmation required
Review basis
One-line + unit documents

Current transformer listings

Compare transformer opportunities

Start with the public ratings below. Call or email Tommy for current availability, pricing, photos and the technical package. Each unit needs project-specific engineering review and remains subject to prior sale.

Kolektor ETRAJJ-138-110-5

Five 110 MVA 138/34.5 kV Kolektor ETRA GSUs

Rating
66/88/110 MVA; 22/29.333/36.666 MVA tertiary
Voltage
138/34.5 kV with 13.8 kV tertiary
Quantity
5 units; matching unit packages available on request
Condition
Brand new, never used and never energized; 2020 factory records reviewed for one unit
Equipment location
Slovenia
Evidence
Five-unit opportunity confirmed by seller; rating plate and FAT package reviewed for one unit

Technical records reviewed

Email for Specs, Price & Availability
Jump to a section

Find a transformer for your project

J&J supplies large power transformers for U.S. projects. Start with a current listing or call Tommy with a requirement beyond the public inventory. GSU, substation, step-down and pad-mounted equipment follow different project specifications.

  • Compare public MVA or kVA, voltage ratio, manufacturer and quantity.
  • Call or email for current availability, price and the documents available for the specific unit.
  • Have your project engineer review the proposed equipment before purchase.
Comparison of transformer duties
Transformer classPrimary dutyDecision inputsNext page
Generator step-up (GSU)Raises generator terminal voltage to a plant or interconnection busGenerator MVA, voltage, PF/reactive range, high-side voltage, impedance, BIL, GCB arrangementGSU transformer page
Substation / powerChanges voltage between transmission, subtransmission, or campus distribution levelsMVA, HV/LV/tertiary, LTC/DETC, BIL, impedance, losses, cooling, fault dutySubstation transformer page
Pad-mountedOutdoor compartmental distribution close to a load blockkVA, primary/secondary, loop/radial, dead/live front, fusing, switch, fluid, enclosurePad-mounted transformer page
Dry-typeIndoor or outdoor distribution where the chosen insulation system and enclosure fit the sitekVA/MVA, voltage, BIL, enclosure, ventilation, temperature rise, sound, harmonics, AHJ requirementsTransformer comparison guide

What makes a transformer a replacement candidate?

A matching voltage ratio is the starting point. Compare the existing transformer and proposed replacement on the same rating basis before reserving equipment. Send the nameplate or one-line by email when available; an initial conversation can begin with MVA, voltages and your required date.

Replacement screening before a commercial offer
CompareWhat the project team needs to confirm
Capacity and coolingRequired MVA at each cooling stage, ambient conditions and operating duty—not only the highest rating.
Winding connectionsHigh, low and tertiary voltages; vector group, phase displacement, neutral and grounding requirements.
System performanceImpedance with its MVA base, tap range and controls, insulation levels, protection and fault-duty requirements.
Installation and scheduleTerminal arrangement, dimensions, accessories, inspection, loading, transport and the needed-on-site date.

What we need to quote a transformer

Start with capacity, phase, frequency, high- and low-side voltages, duty, site, and needed-on-site date. To confirm a technical match, we may also need BIL, impedance, cooling, vector group, neutral and taps, fluid, losses, harmonics, site conditions, sound limits, and shipping constraints.

  • Capacity: base kVA/MVA and every cooling-stage rating; do not substitute MW for MVA.
  • Voltage: nominal and maximum-system values for each winding, plus generator terminal voltage where applicable.
  • Insulation and system: BIL, grounding, vector or winding connection, phase displacement, impedance and its MVA/tap/temperature basis.
  • Regulation: LTC or DETC range, steps, control requirements, and parallel-operation constraints.
  • Site: minimum/maximum ambient, altitude, seismic, wind, sound, footprint, terminals, access, route, and installation state.
  • Evidence: one-line, nameplate, outline, schematic, test report, losses, oil/fluid data, maintenance and preservation records when available.

Transformer voltage classes

We screen requirements in the 69, 115, 138, 161, 230, and 345 kV classes when a source and supporting records are available. Ratios such as 230/34.5, 138/34.5, 230/13.8, 345/34.5, and 230/69 kV are common searches, but the ratio alone never establishes a technical fit.

High-voltage transformer search inputs
HV classExample search ratiosProject team must confirm
69 / 115 kV69/13.8 · 115/34.5MVA, maximum system voltage, BIL, impedance, vector, taps, duty, site
138 / 161 kV138/34.5 · 138/13.8 · project-specific 161 kV ratiosGenerator or substation duty, tertiary, grounding, cooling, losses, documents
230 kV230/34.5 · 230/13.8 · 230/69Complete winding schedule, BIL, impedance basis, OLTC/DETC, terminals, logistics
345 kV345/34.5 and project-specific ratiosCollector/grid duty, tertiary, switching cases, transport, tests, project approval

Examples describe project search patterns, not guaranteed inventory. Review current opportunities or send an equipment request for a written match.

Which standards and tests apply to power transformers?

The applicable standard depends on the transformer class, voltage, construction, duty, owner specification, and manufacture date. Current reviews may reference IEEE C57.12.00 general requirements, IEEE C57.12.90 test methods, current class-specific standards, selected IEC 60076 parts, and federal efficiency rules only where the exact equipment falls within their scope.

Applicable standards, listings, tests, and efficiency requirements are confirmed for each quoted unit; naming a standard is not a certification claim.

Routine, design, and special tests are not interchangeable. A page may describe available test categories, but only the certified report or agreed test plan proves what a specific serial number has passed.

How should new, surplus, used and reconditioned transformers be compared?

Condition labels are the start of diligence, not the conclusion. Procurement should compare serial-specific records, storage and transport history, preservation, missing accessories, inspection access, test scope, warranty provider, field work, freight, and schedule before assigning value to a condition label.

Transformer condition review
ConditionVerifyCommon risk
New factory orderApproved specification, drawings, materials, factory milestones, test plan, warranty and delivery termInterfaces or approvals remain open; factory date is not delivered date
Unused surplusTitle/authority, serial, storage, preservation, test status, completeness and warranty transferBuilt for another project; ratio, impedance, vector, terminals or accessories may not fit
UsedService history, DGA/moisture, electrical tests, bushings, leaks, corrosion, loading, faults and transportUnknown events or no baseline records
ReconditionedWork scope, parts, shop tests, responsible party and warranty“Reconditioned” may describe very different work scopes

What does J&J include in a transformer procurement review?

A quote should identify the exact offered scope and the evidence actually available. J&J requests the nameplate, rating sheet, outline, schematics, test and loss data, fluid information, accessory and spare lists, condition evidence, current location, shipping configuration, Incoterm, warranty provider, availability date, exclusions, and quote validity.

Availability is subject to prior sale, technical review, and written confirmation by J&J Transformers LLC.

Common questions

Written quotes and supporting records control unit-specific ratings, availability, condition, price, and delivery.

Can J&J supply a transformer outside the listed inventory?

Yes. Email the required MVA or kVA, high- and low-side voltages, quantity and needed-on-site date. J&J reviews additional supply options for the requirement. Supply capability does not establish that a particular configuration is in stock.

Does a transformer listed at 230 kV necessarily have a 34.5 kV secondary?

No. The high-side voltage class does not identify the low-side or tertiary voltage. Use the exact-ratio pages or the listing's full voltage description, then request the records for that unit.

How do I get prices, photos and technical documents?

Call Tommy Marco at 346-276-9540 or email tommy@jjtransformers.com. Specifications, reports, photos and pricing are shared directly after contact, according to the records available for the proposed unit. Availability remains subject to prior sale and written confirmation.

Which transformer type should I request?

Choose by duty: GSU for generator export, substation/power transformer for network or campus voltage transformation, and pad-mounted for compartmental medium-voltage distribution near loads.

What ratings are required for a transformer quote?

Start with kVA/MVA, high and low voltage, phase, frequency, duty, site, and date; provide BIL, impedance, cooling, vector group, taps, site conditions, and documents when known.

Why are BIL and impedance important?

BIL supports insulation coordination. Impedance affects fault current, regulation, reactive behavior, protection, and parallel operation. Both must match the system studies and purchaser specification.

Can an existing transformer be matched?

Yes, after its nameplate, one-line, outline, schematics, test data, site conditions, and interface requirements are compared to candidate units.

Can J&J supply a 125 MVA transformer?

Yes, J&J can screen a 125 MVA requirement when the project team supplies the complete duty, cooling-stage ratings, high- and low-side voltages, frequency, BIL, impedance basis, vector and grounding, OLTC or DETC requirement, site, condition acceptance, documents, quantity, and project timing. This is a supply capability, not a claim that a matching 125 MVA unit is currently available.

Are used transformers acceptable for data centers?

That is an owner and engineering decision based on condition, evidence, tests, remaining-life assessment, warranty, reliability architecture, and project requirements.

Does every transformer comply with the same standard?

No. Standards and efficiency rules vary by transformer class, construction, voltage, duty, jurisdiction, purchaser specification, and manufacture date.

Can freight be included?

Yes when defined. The written quote should state origin, destination, shipping configuration, mode, permits, Incoterm, unloading boundaries, taxes/tariffs, and exclusions.

How is availability confirmed?

Through written confirmation tied to the specific equipment and quote date after ownership, technical, condition, location, scope, and commercial review.

Call Email Sales