500 kV Transformers for Sale

Review three Royal SMIT transformers for a 500 kV system requirement. Their actual nameplate is 525/69 kV: 240/320/400 MVA step-up cooling stages, with a separate 250 MVA maximum step-down duty. Request the technical package, price and release schedule; system suitability requires project engineering review.

J&J Transformers LLC · Sugar Land, Texas · Serving projects nationwide

For transmission and hyperscale teams reviewing a 500 kV-class requirement against the actual 525/69 kV candidate. Send source and output voltage, required continuous MVA, duty, quantity, specification and needed-on-site date.

Tommy Marco · tommy@jjtransformers.com

System requirement
500 kV class
Candidate nameplate
525/69 kV
Quantity
3 offered units
Step-down limit
250 MVA

The comparison below shows the actual 525/69 kV Royal SMIT candidate for review against a 500 kV system requirement. Its maximum step-down duty is 250 MVA; no automatic system compatibility is asserted.

Current power equipment inventory

Compare the complete published ratings, condition and dated offer evidence below. Select two or three listings for a detailed comparison, or switch to photos and details. A listing can contain several units; the quantity is separate from the number of selected listings.

525 kV results

525 kV transformer listings

Open the 525 kV page
Current listings. Availability requires written confirmation.
CompareUnitMVA ratingVoltageConditionContact
Royal SMIT 525/69 kV Transformers — 3 AvailableJJ-SMIT-525-3240/320/400 MVA; 250 MVA maximum step-down; 90 MVA tertiary525/69 kV with 13.7 kV buried-delta tertiary2022 manufacture shown in supplied nameplate; condition and service history confirmed with quotation Request more infoView details
About availability & equipment records

Compare each listing's rating, condition, frequency, package scope and evidence. Generator and turbine positions are based on received offers or J&J's dated availability updates, as stated in each record. Record-review dates are not new availability checks. Call or email Tommy with the J&J reference for specifications, price, current allocation and delivery terms.

Jump to a section

Choose a listing and request its current offer

The comparison above shows the actual equipment records for this winding class. Keep existing equipment, submitted offers and future production separate. A listing's quantity is distinct from the quantity reserved for your order.

Choose the exact winding ratio or project quantity

Use the required main-winding voltage pair to choose equipment. For a multi-unit project, give each ratio and delivery phase its own quantity.

Prepare a 500 kV transformer buying request

The Royal SMIT candidate shown for 500 kV-class project screening is nameplated 525/69 kV. Retain those actual ratings and its 250 MVA maximum step-down limit. The project team reviews taps, insulation, duty, grounding and system compatibility before a 500 kV application is accepted.

Review the 525/69 kV Royal SMIT candidate

The public equipment record includes the supplied nameplate, outline drawing and factory test report. It distinguishes 400 MVA step-up rating from the 250 MVA step-down limit. Ask for unit-specific condition, matching records, inspection access and the included equipment schedule.

What is needed to review a 500 kV substation or GSU requirement?

Send the utility or project specification and one-line with the required MVA, operating direction, low-side voltage, winding connections, insulation levels, impedance, tap range, quantity and delivery date. The project engineer and utility review the actual nameplate and factory records; no automatic 500 kV compatibility is claimed.

Request price, availability and delivery

Contact Tommy Marco at 346-276-9540 or tommy@jjtransformers.com. Include the listing ID if you have one, MVA, exact voltage ratio, quantity, acceptable condition, site and required delivery date. J&J serves U.S. projects nationwide from Sugar Land, Texas.

  • Choose new or unused surplus, used, rebuilt or reconditioned equipment; condition is stated for the specific offered unit.
  • Request photos, nameplate, drawings, available tests, included accessories and inspection terms.
  • Confirm price, freight or delivered scope, loading, warranty, payment terms and the agreed delivery milestone in writing.

500 kV step-down transformer requirements

For a 500 kV step-down request, provide both source and output winding voltages, required continuous MVA, quantity and project date. Compare the candidate's actual operating-direction limits, winding connections, grounding, taps, impedance, insulation and installation interfaces. The voltage page remains a screening route; the step-down hub explains duty and quotation evidence.

The Royal SMIT 525/69 kV record lists 240/320/400 MVA cooling stages and a separate 250 MVA maximum for step-down duty. The 400 MVA step-up rating is not a 400 MVA step-down rating. Its 13.7 kV buried-delta tertiary is not presented as an accessible external load supply.

Evidence path for a 500 kV-class transformer review

Use three separate records: the public screening facts, the private technical package and the written commercial offer. This keeps a useful buying page from being mistaken for a technical approval, guaranteed allocation or delivery commitment.

J&J shares sensitive serial-specific and seller documents directly after the equipment and project requirement are qualified. Public pages do not disclose private owner, customer, supplier or storage information.

Evidence to retain before purchase approval
Evidence stageWhat to confirm
Public screening recordThe public candidate is identified by its actual 525/69 kV Royal SMIT nameplate class, 240/320/400 MVA step-up stages and separate 250 MVA maximum step-down limit. A 500 kV system match is not assumed.
Private technical packageRequest the available unit identity, nameplate and drawings, test and preservation records, accessories and shipping information for engineering review against the actual system requirement.
Written commercial offerThe written offer confirms which units are included, current availability, operating-direction limit, price, warranty, port or site delivery scope and schedule.

For worksheets, specifications or supporting documents, call 346-276-9540 or email tommy@jjtransformers.com. Files are shared directly after contact.

Common questions

Written quotes and supporting records control unit-specific ratings, availability, condition, price, and delivery.

How do I request a transformer price and availability?

Email tommy@jjtransformers.com or call Tommy Marco at 346-276-9540. Send the listing reference or required MVA, exact winding voltages, quantity, destination and needed-on-site date. Ask for specifications, price, current allocation and delivery terms. Written confirmation is required; subject to prior sale.

Are every listing and production allocation ready to ship?

No. Existing equipment, submitted inventory and factory production allocations have different release schedules. TSEA allocations are for 2027 and are not immediately shipping stock. Ask for current written allocation, preparation requirements, included accessories and the delivery milestone for each offered unit.

Is the Royal SMIT candidate a 400 MVA step-down transformer?

No. Its published step-up cooling stages are 240/320/400 MVA at 525/69 kV. The separate maximum step-down duty is 250 MVA. Confirm the actual operating direction, winding connection and permitted duty against the project's engineering requirements.

Does a transformer offer include a complete substation?

Only equipment expressly included in the quotation is supplied. Specify the transformer, breakers, switchgear, protection, controls and site-work responsibilities separately when requesting a complete package.