Transmission-to-transmission transformer requirements

230/69 kV Autotransformers for Sale

J&J Transformers LLC offers a published ABB autotransformer record with a 230 kV high side and a reconnectable 115 or 69 kV lower-voltage winding. For a 230/69 kV requirement, compare the selected connection, cooling and temperature-rise ratings, neutral arrangement, tertiary duty and available documents. Request the current quantity, price, release terms and delivery scope directly from Tommy.

J&J Transformers LLC · Sugar Land, Texas · Serving projects nationwide

Tommy Marco · tommy@jjtransformers.com

Windings
230/69 kV
Candidates
1 published records
Evidence
Listed per opportunity
Quote
Current written terms

Current power equipment inventory

Compare the complete published ratings, condition and dated offer evidence below. Select two or three listings for a detailed comparison, or switch to photos and details. A listing can contain several units; the quantity is separate from the number of selected listings.

230 kV results

230 kV transformer listings

Open the 230 kV page
Current listings. Availability requires written confirmation.
CompareUnitMVA ratingVoltageConditionContact
112 MVA-Class ABB 230/115/69 kV AutotransformerJJ-ABB-AUTO-11260/80/100 MVA at 55 C; 67.2/89.6/112 MVA at 65 C230 kV to reconnectable 115 or 69 kV with 13.5 kV delta tertiaryBrand new, never used and never energized Request more infoView details
About availability & equipment records

Compare each listing's rating, condition, frequency, package scope and evidence. Generator and turbine positions are based on received offers or J&J's dated availability updates, as stated in each record. Record-review dates are not new availability checks. Call or email Tommy with the J&J reference for specifications, price, current allocation and delivery terms.

Jump to a section

Compare the 230/69 kV equipment records

The comparison uses the same public records as J&J's inventory. A candidate's stated quantity, condition and evidence basis stay attached to that record. A public opportunity is a starting point for the technical package and current written offer.

Published candidates - exact unit identity and current availability confirmed through J&J
Equipment recordPublished MVAListed quantityCondition and evidence basis
ABB · JJ-ABB-AUTO-11260/80/100 MVA at 55 C; 67.2/89.6/112 MVA at 65 C1 nameplate-documented opportunity; available quantity to confirmBrand new, never used and never energized. Serial-specific nameplate photograph reviewed

What matters when buying a 230/69 kV transformer?

The 115 and 69 kV values describe a reconnectable winding choice, not two simultaneously available output buses. Ask for the selected connection drawing and its permitted rating. Keep 60/80/100 MVA at 55 C separate from 67.2/89.6/112 MVA at 65 C, and review any tertiary use against its documented duty. An autotransformer has a different connection and isolation arrangement from a separate-winding transformer.

  • Compare required continuous MVA with the actual cooling-stage and temperature-rise ratings.
  • Identify new-project, spare, replacement or proposed parallel-operation duty.
  • Request the nameplate, connection and outline drawings, available tests, condition history and included accessories.

New, unused or reconditioned: compare the actual offer

State the condition your project accepts, then review the selected record's identity, service or preservation history, inspection scope and written availability. Submitted inventory and design records require their own confirmation; an unused description does not establish a current warranty or a ready-to-ship package.

Request a 230/69 kV price and delivery quote

Call Tommy Marco at 346-276-9540 or email tommy@jjtransformers.com with the required ratings, quantity, destination and needed-on-site date.

  • Include MVA by required cooling duty, the complete winding schedule and one-line or specification.
  • Give quantity, acceptable condition, inspection/document requirements and delivery phases.
  • Ask for the offered unit, accessories, warranty, loading, freight and site-arrival scope in writing.

ABB 230/69 kV candidate: compare the actual rating basis

The published ABB record gives reconnectable 115 or 69 kV lower-voltage duty. Review the selected winding connection and temperature-rise basis before choosing the required continuous MVA. The equipment title's 112 MVA class does not replace the 55 C rating schedule.

Published ABB autotransformer cooling-stage ratings
Temperature-rise basisPublished MVA stagesPurchase review
55 C60 / 80 / 100 MVAUse the stage allowed by the actual cooling and project operating conditions
65 C67.2 / 89.6 / 112 MVAConfirm permitted duty and the selected winding configuration with the nameplate and project engineer
Lower-voltage connection115 kV or 69 kV reconnectable windingRequest the connection drawing; these are not two simultaneous output buses

Common questions

Written quotes and supporting records control unit-specific ratings, availability, condition, price, and delivery.

Does J&J sell 230/69 kV transformers?

J&J Transformers LLC offers a published ABB autotransformer record with a 230 kV high side and a reconnectable 115 or 69 kV lower-voltage winding. For a 230/69 kV requirement, compare the selected connection, cooling and temperature-rise ratings, neutral arrangement, tertiary duty and available documents. Request the current quantity, price, release terms and delivery scope directly from Tommy.

How do I get a 230/69 kV transformer price?

Call Tommy Marco at 346-276-9540 or email tommy@jjtransformers.com with the required ratings, quantity, destination and needed-on-site date. Include the exact unit reference if you have selected a listing. Pricing and delivery apply to the confirmed configuration and included scope.

Can I request a 230/69 kV transformer that is not listed?

Yes. Send the requirement to Tommy with continuous MVA, winding connections, operating duty, quantity and required date. J&J can review other sourcing options; an inquiry is not a statement that every configuration is in stock.

Are matching 230/69 kV units automatically interchangeable?

No. Compare the exact connection, grounding, impedance and base, taps, insulation, frequency, cooling, condition and physical interfaces. A same-ratio candidate needs project-specific engineering acceptance, especially for parallel operation or a different operating direction.

Which ABB rating should I use for a 230/69 kV quotation?

State the required continuous MVA and permitted temperature-rise basis. The published record gives 60/80/100 MVA at 55 C and 67.2/89.6/112 MVA at 65 C. The selected 69 kV connection, cooling stage, operating duty and project acceptance must be confirmed against the actual nameplate and drawings.