Power transformer buying

Large Power Transformers for Sale

J&J supplies large power transformers for utilities, industrial projects, generation and data centers. The candidates below have at least one published main nameplate rating of 100 MVA or more; that does not establish the usable rating for every operating duty. Compare all cooling stages and winding limits, then confirm current condition, technical fit, allocation and the complete delivery scope in writing.

J&J Transformers LLC · Sugar Land, Texas · Serving projects nationwide

Tommy Marco · tommy@jjtransformers.com

Match
MVA · winding voltages · duty
Condition
Unit-specific records
Availability
Written confirmation
Contact
Tommy Marco

Current transformer listings

Compare transformer opportunities

Start with the public ratings below. Call or email Tommy for current availability, pricing, photos and the technical package. Each unit needs project-specific engineering review and remains subject to prior sale.

Royal SMITJJ-SMIT-525-3

Royal SMIT 525/69 kV Transformers — 3 Available

Rating
240/320/400 MVA; 250 MVA maximum step-down; 90 MVA tertiary
Voltage
525/69 kV with 13.7 kV buried-delta tertiary
Quantity
3 units
Condition
2022 manufacture shown in supplied nameplate; condition and service history confirmed with quotation
Equipment location
International; dispatch location confirmed with quotation
Evidence
Supplied nameplate, outline drawing and factory acceptance test report

Technical records reviewed

Email for Specs, Price & Availability
Kolektor ETRAJJ-138-110-5

Five 110 MVA 138/34.5 kV Kolektor ETRA GSUs

Rating
66/88/110 MVA; 22/29.333/36.666 MVA tertiary
Voltage
138/34.5 kV with 13.8 kV tertiary
Quantity
5 units; matching unit packages available on request
Condition
Brand new, never used and never energized; 2020 factory records reviewed for one unit
Equipment location
International; dispatch location confirmed with quotation
Evidence
Five-unit opportunity confirmed by seller; rating plate and FAT package reviewed for one unit

Technical records reviewed

Email for Specs, Price & Availability
ABB Ltda.JJ-ABB-AUTO-112

112 MVA-Class ABB 230/115/69 kV Autotransformer

Rating
60/80/100 MVA at 55 C; 67.2/89.6/112 MVA at 65 C
Voltage
230 kV to reconnectable 115 or 69 kV with 13.5 kV delta tertiary
Quantity
1 nameplate-documented opportunity; available quantity to confirm
Condition
Brand new, never used and never energized
Equipment location
USA
Evidence
Serial-specific nameplate photograph reviewed

Technical records reviewed

Email for Specs, Price & Availability
ILJIN ElectricJJ-ILJIN-230-167

ILJIN 167 MVA 230/34.5 kV New / Unused Transformer

Rating
100/133/167 MVA
Voltage
230/34.5 kV; tertiary voltage to confirm
Quantity
1 represented unit
Condition
New / unused and never energized, as explicitly represented in the offer
Equipment location
International; dispatch location confirmed with quotation
Evidence
Individual written offer, repeated in a September 30 equipment listing

Technical records reviewed

Email for Specs, Price & Availability
Manufacturer disclosed in the qualified technical packageJJ-TX-201

208 MVA 138/34.5 kV Stored Surplus Transformer

Rating
125/166/208 MVA
Voltage
138 kV HV / 34.5 kV LV
Quantity
1 offered position
Condition
Surplus in storage; service history requires confirmation
Equipment location
Dispatch location confirmed with quotation
Evidence
Supplied design data sheet; final unit-specific nameplate and FAT pending

Technical records reviewed

Email for Specs, Price & Availability
Manufacturer disclosed in the qualified technical packageJJ-TX-204

345/34.5 kV Transformer Production Positions

Rating
266 MVA offered; final rating requires reconciliation
Voltage
345 kV HV / 34.5 kV LV
Quantity
2 offered positions
Condition
Factory manufacturing position; completion pending
Equipment location
Dispatch location confirmed with quotation
Evidence
Seller offer summary; exact cooling stages require confirmation

Technical records reviewed

Email for Specs, Price & Availability
Manufacturer disclosed in the qualified technical packageJJ-TX-205

116 MVA 138 kV Transformer Positions — 2027

Rating
116 MVA stated maximum
Voltage
138 kV HV; secondary voltage requires confirmation
Quantity
2 offered positions
Condition
Factory manufacturing position; completion pending
Equipment location
Dispatch location confirmed with quotation
Evidence
Seller offer summary; exact cooling stages require confirmation

Technical records reviewed

Email for Specs, Price & Availability
ABB Power T&DJJ-TX-208

ABB 133 MVA 115/13.2 kV Pre-Owned GSU

Rating
80/106.67/133.33 MVA at 55C rise; 89.6/119.47/149.33 MVA at 65C rise
Voltage
115 kV grounded wye / 13.2 kV delta
Quantity
One offered unit; subject to prior sale and written allocation
Condition
Pre-owned installed surplus; detailed service history requires confirmation
Equipment location
Location confirmed with quotation
Evidence
OEM nameplate and supplied technical packet

Technical records reviewed

Email for Specs, Price & Availability
Jump to a section

Compare all MVA cooling stages

A multi-stage nameplate can state different MVA ratings for different cooling arrangements. Confirm the required continuous duty, temperature-rise basis, available cooling equipment, auxiliaries and site conditions. State which rating is required rather than selecting the largest number on the nameplate.

Step-up and step-down duty can have different limits

The Royal SMIT 525/69 kV record illustrates why duty matters: it lists 240/320/400 MVA cooling stages, while the stated maximum step-down duty is 250 MVA. The 400 MVA figure must not be used as a 400 MVA step-down offer. Apply the same winding and duty review to every large transformer.

What belongs in a large transformer purchase specification?

Provide the main and tertiary winding voltages and duties, MVA stages, connections, frequency, insulation levels, impedance and its base, tap requirements, cooling and monitoring requirements, quantity and project schedule. Review outline drawings, terminal positions and the unit's supporting test records.

Plan loading, transport and site receiving

Request shipping dimensions and weights, oil and accessory shipping configuration, loading arrangements, transport scope and the receiving-site offloading plan. Separate unit release, preparation, shipment, arrival and energization dates. Agree on responsibilities in the quotation instead of assuming freight or a crane is included.

Large power transformer price and availability

Price depends on the exact unit, condition, included accessories, documentation, inspection, preparation and delivery scope. Send your one-line or specification and required site date for a comparable quotation. Listings remain subject to prior sale; a record-review date does not reserve a unit.

Common questions

Written quotes and supporting records control unit-specific ratings, availability, condition, price, and delivery.

Does J&J supply 100 MVA and larger transformers?

J&J publishes large transformer records with main nameplate stages at or above 100 MVA. Usable duty, winding limits, condition, current allocation and delivery are confirmed for the exact unit and application.

Is the highest MVA rating the continuous rating I can use?

Only if the stated cooling arrangement, temperature-rise basis, winding duty and required auxiliaries support that rating under the approved project conditions. Review the complete nameplate and engineering requirements.

Can I use a GSU transformer as a step-down transformer?

Do not assume interchangeability. The responsible engineer must review winding duty, any direction-specific limits, connections, grounding, taps, impedance, insulation and protection against the project specification.

Call Email Sales