| Unit ID | JJ-WEST-115-22-2 |
|---|---|
| Manufacturer | Westinghouse |
| Manufacturer basis | Received written equipment offer; individual nameplates require review |
| Rating | 12/16/20/22.4 MVA; rating-stage basis to confirm |
| Voltage / output | 115/24.9 kV |
| Frequency | Not documented; confirm with J&J |
| Received offer date | |
| Vector group | Winding connections to confirm |
| Tertiary | Not documented; confirm the complete winding arrangement |
| Quantity | 2 represented units |
| Availability | Offered September 20, 2026; current availability and allocation require written confirmation |
| Condition basis | Pre-owned / reconditioned; new bushings represented in the offer |
| Current location | Location confirmed with quotation |
| Listing information reviewed |
Technical values and record basis
Received written offer; individual nameplates have not been reviewed.
| Reconditioning scope represented | New bushings; other work scope requires matching records |
|---|---|
| Rating-stage basis | 12 / 16 / 20 / 22.4 MVA represented; cooling and temperature-rise stages to confirm |
Details to confirm for this listing
- Both individual nameplates, frequency, connections, cooling, rise, impedance/base, BIL and taps
- Current condition, tests, detailed reconditioning scope, dimensions/weights and accessories
Technical highlights
- The written offer identifies two Westinghouse units with the stated 115/24.9 kV ratio and four MVA ratings.
- Pre-owned/reconditioned condition and new bushings are offer representations. Obtain the work scope and present inspection findings before purchase.
- Request a readable nameplate for each unit, the rating-stage and temperature-rise basis, winding connections, frequency, taps, impedance and current tests.
- Confirm accessories, any included breakers, loading, transport and release timing with the quotation. The review date is not a fresh availability check.
Evidence reviewed
Received written equipment offer; individual nameplates require review
Records apply only to the stated unit or design basis.
Availability and terms
Offered September 20, 2026; current availability and allocation require written confirmation
Ask for the current technical package, price, included accessories and delivery terms.
Confirm the purchase and delivery scope
Ask J&J to confirm the proposed unit’s allocation, price, inspection access, included accessories, loading and freight boundary, receiving arrangements, release schedule, deposit or reservation terms and any applicable warranty. Photos, matching records and inspection arrangements are coordinated through J&J.
Request written termsCheck this transformer against your project
Compare the complete winding arrangement and condition evidence before requesting a quote. A matching voltage ratio alone does not establish suitability.
- Match MVA, voltage, impedance, taps and winding connections
- Review seven transformer condition risks before purchase
For this listing’s photographs, reports, pricing and current status, call 346-276-9540 or email Tommy with unit ID JJ-WEST-115-22-2.