Review 10 transformer and generator opportunities, including several multi-unit packages. Each summary is evidence-qualified and remains subject to seller reconfirmation, technical fit, prior sale, and written commercial terms; request the current drawings, nameplates, and test records before relying on a listing.

Current-status policy: Listings are subject to seller reconfirmation, technical review, prior sale, and written commercial terms. The project one-line and specification control suitability.

TransformerJJ-GA283A

2020 Georgia Transformer GA283A 180/240/300 MVA 138/34.5 kV Transformer

Manufacturer
Georgia Transformer
Manufacturer basis
Serial-specific nameplate reviewed
Rating
180/240/300 MVA; 63/84/105 MVA tertiary
Voltage / output
138/34.5 kV with 12 kV buried-delta tertiary
Quantity
1 documented unit - GA283A
Condition
2020 nameplate; current condition requires confirmation
Location
Provided after qualified RFQ
  • ONAN/ONAF/ONAF, 60 Hz, three-phase, vector group YNyn0+d1
  • Measured 138/34.5 kV impedance: 9.67% on a 180 MVA base
  • Copper windings, conservator system, Type II mineral oil, and HV OLTC

Nameplate package reviewed; availability requires written reconfirmation

TransformerJJ-G5058-03-01

Prolec GE 132/176/220 MVA 345/34.5 kV Collector Step-Up Transformer

Manufacturer
Prolec GE
Manufacturer basis
Serial-specific nameplate and approval drawings reviewed
Rating
132/176/220 MVA; 46.2/61.6/77 MVA tertiary
Voltage / output
345/34.5 kV with 13.8 kV delta tertiary
Quantity
1 documented unit - G5058-03-01
Condition
Approval drawings reviewed; current condition requires confirmation
Location
Provided after qualified RFQ
  • Collector step-up duty; ONAN/ONAF/ONAF, 60 Hz, three-phase
  • Grounded-wye / grounded-wye / delta winding configuration
  • Nominal design H-X impedance: 12.0% on a 132 MVA base

Engineering package reviewed; availability requires written reconfirmation

TransformerJJ-GA447A

Georgia Transformer 108/144/180 MVA 345/34.5 kV Transformer

Manufacturer
Georgia Transformer
Manufacturer basis
Serial-specific approval drawings and FAT report reviewed
Rating
108/144/180 MVA; 37.8/50.4/63 MVA tertiary
Voltage / output
345/34.5 kV with 12 kV buried-delta tertiary
Quantity
1 documented unit - GA447A
Condition
Factory acceptance tested September 2024; current condition requires confirmation
Location
Provided after qualified RFQ
  • ONAN/ONAF1/ONAF2, 60 Hz, three-phase, vector group YNyn0+d1
  • Measured H-X impedance: 6.99% on a 108 MVA base
  • Factory test report concludes results were within technical tolerances

Approval drawings and FAT report reviewed; availability requires reconfirmation

TransformerJJ-GA424A

Georgia Transformer 72/96/120 MVA 138/34.5 kV Solar GSU

Manufacturer
Georgia Transformer
Manufacturer basis
Serial-specific nameplate and approval drawings reviewed
Rating
72/96/120 MVA; 25.2/33.6/42 MVA tertiary
Voltage / output
138/34.5 kV with 12 kV buried-delta tertiary
Quantity
1 documented unit - GA424A
Condition
Approval drawings reviewed; current condition requires confirmation
Location
Provided after qualified RFQ
  • Solar GSU design; ONAN/ONAF1/ONAF2, 60 Hz, three-phase
  • Vector group YNyn0+d1 with HV OLTC and conservator oil system
  • Nameplate rating is used; an outline-drawing discrepancy requires final seller confirmation

Engineering package reviewed; availability requires written reconfirmation

TransformerJJ-KETRA-84097

Five 2020 Kolektor ETRA 66/88/110 MVA 138/34.5 kV GSU Transformers

Manufacturer
Kolektor ETRA
Manufacturer basis
Five-unit opportunity confirmed by seller; rating plate and FAT package for serial 84097 reviewed
Rating
66/88/110 MVA; 22/29.333/36.666 MVA tertiary
Voltage / output
138/34.5 kV with 13.8 kV tertiary
Quantity
5 total units represented; serial-specific package reviewed for 84097
Condition
2020 factory records reviewed for serial 84097; current condition of all five units requires confirmation
Location
Current location requires reconfirmation
  • GSU duty; ONAN/ONAF1/ONAF2, 60 Hz, three-phase, vector group YNyn0+d11
  • Measured impedance: 13.41% on a 110 MVA base at nominal tap
  • 2020 factory tests passed; those records do not establish current condition
  • Seller confirms a five-unit opportunity; request all five serial-specific nameplates before quotation

5 units represented; availability and the remaining four serial-specific packages require written reconfirmation

TransformerJJ-HB533-2

Virginia Transformer 50.4/67.2/84 MVA 115/34.5 kV Transformers

Manufacturer
Virginia Transformer Corp.
Manufacturer basis
Two-unit nameplate design sheet reviewed
Rating
50.4/67.2/84 MVA
Voltage / output
115 kV delta / 34.5 kV grounded wye
Quantity
2 documented unit IDs - HB533A and HB533B
Condition
Nameplate design reviewed; manufacture date and condition require confirmation
Location
Provided after qualified RFQ
  • ONAN/ONAF/ONAF, 60 Hz, three-phase, vector group Dyn1
  • Copper windings, Type II mineral oil, and Reinhausen HV LTC
  • Designed impedance: 9.02% on a 50.4 MVA base; final tested value is not shown

Two-unit design package reviewed; availability requires written reconfirmation

TransformerJJ-HB501-3

Virginia Transformer 36/48/60 MVA 115/34.5 kV Transformers

Manufacturer
Virginia Transformer Corp.
Manufacturer basis
Three unit-specific nameplates reviewed
Rating
36/48/60 MVA
Voltage / output
115 kV delta / 34.5 kV grounded wye
Quantity
3 documented units - HB501A, HB501B, and HB501C
Condition
February-March 2026 nameplates; current condition requires confirmation
Location
Provided after qualified RFQ
  • ONAN/ONAF/ONAF, 60 Hz, three-phase, vector group Dyn1
  • Measured impedance: 8.42%, 8.41%, and 8.46% at 36 MVA by unit
  • Copper windings, Type II mineral oil, and ABB HV LTC

Three unit-specific nameplates reviewed; availability requires reconfirmation

TransformerJJ-JL3023

IEN Hanchang 30-56 MVA 138/13.8 kV Substation Transformer

Manufacturer
IEN Hanchang / JCL Energy
Manufacturer basis
Project-specific approval drawings reviewed
Rating
30/39.9/50 MVA at 55 C; 33.6/44.7/56 MVA at 65 C
Voltage / output
138 kV delta / 13.8 kV grounded wye
Quantity
1 design package represented - JL3023
Condition
2024 approval drawings reviewed; serial and current condition require confirmation
Location
Provided after qualified RFQ
  • Oil-immersed substation transformer; ONAN/ONAF/ONAF, 60 Hz, three-phase
  • HV de-energized tap range: 131.1-144.9 kV
  • Final impedance, serial number, test data, and manufacture date are not populated

Approval drawing package reviewed; availability requires written reconfirmation

TransformerJJ-230-220-1

ABB / Hitachi 220 MVA 230/34.5 kV Transformer Opportunity

Manufacturer
ABB / Hitachi
Manufacturer basis
Seller represented; written reconfirmation required
Rating
220 MVA represented
Voltage / output
230/34.5 kV represented
Quantity
1 unit represented
Condition
Current condition requires reconfirmation
Location
Provided after qualified RFQ
  • Exact serial, nameplate, cooling, vector group, tests, and included scope require confirmation
  • Seller authority and current availability require reconfirmation
  • No compatibility or delivery claim is made from the summary alone

Open for technical screening; full package requires written reconfirmation

GeneratorJJ-J420-MULTI

Jenbacher J420 Natural-Gas Generator Opportunity

Manufacturer
INNIO Jenbacher
Manufacturer basis
Seller represented; serials and package identity require confirmation
Rating
Approximately 1.5 MW each represented
Voltage / output
60 Hz represented; output voltage to confirm
Quantity
Multi-unit opportunity represented
Condition
Current condition requires reconfirmation
Location
United Kingdom port represented
  • Serials, output basis, hours, starts, maintenance, emissions suitability, controls, and included scope require confirmation
  • Import, freight, and project applicability require review
  • Availability remains subject to prior sale

Open for technical screening; quantity and package require confirmation

Additional sourcing request

Do not see your exact unit? Let us source it.

The public list is not a complete statement of supply. Send the MVA or MW rating, primary and secondary voltage, quantity, project location, and required date; J&J will screen current owner-authorized opportunities and documented sources without implying that an unlisted unit is already controlled or available.