Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Unused and never-energized transformer supply

Surplus Power Transformers for Sale

J&J buys and sells surplus power transformers, unused project equipment, canceled-project units and selected rebuilt transformers. Compare each listing's stated condition with its nameplate, drawing, test and storage records. Surplus describes why a unit is offered; it does not establish that it is new or service-ready. Send the J&J reference and your project specification for price, technical records and current availability.

J&J Transformers LLC · Sugar Land, Texas · Serving projects nationwide

Tommy Marco · tommy@jjtransformers.com

Search method
Selected public records + private matching
Condition
Unused · never energized · project-released
Evidence
Serial-specific records preferred
Availability
Current written confirmation

Current transformer listings

Compare transformer opportunities

Start with the public ratings below. Call or email Tommy for current availability, pricing, photos and the technical package. Each unit needs project-specific engineering review and remains subject to prior sale.

ABBJJ-ABB-AUTO-112

112 MVA-Class ABB 230/115/69 kV Autotransformer

Rating
60/80/100 MVA at 55 C; 67.2/89.6/112 MVA at 65 C
Voltage
230 kV to reconnectable 115 or 69 kV with 13.5 kV delta tertiary
Quantity
1 nameplate-documented opportunity; available quantity to confirm
Condition
Brand new, never used and never energized
Equipment location
USA
Evidence
Serial-specific nameplate photograph reviewed
Availability confirmedConfirmed by J&J Request current allocation and release terms · subject to prior sale
Email for Specs, Price & Availability
Royal SMITJJ-SMIT-525-3

Royal SMIT 525/69 kV Transformers — 3 Available

Rating
240/320/400 MVA; 250 MVA maximum step-down; 90 MVA tertiary
Voltage
525/69 kV with 13.7 kV buried-delta tertiary
Quantity
3 units
Condition
2022 manufacture shown in supplied nameplate; condition and service history confirmed with quotation
Equipment location
International; dispatch location confirmed with quotation
Evidence
Supplied nameplate, outline drawing and factory acceptance test report
Availability confirmedConfirmed by J&J 4–8 weeks to shipRequest current allocation and release terms · subject to prior sale
Email for Specs, Price & Availability
Kolektor ETRAJJ-138-110-5

Five 110 MVA 138/34.5 kV Kolektor ETRA GSUs

Rating
66/88/110 MVA; 22/29.333/36.666 MVA tertiary
Voltage
138/34.5 kV with 13.8 kV tertiary
Quantity
5 units; matching unit packages available on request
Condition
Brand new, never used and never energized; 2020 factory records reviewed for one unit
Equipment location
International; dispatch location confirmed with quotation
Evidence
Five-unit opportunity confirmed by seller; rating plate and FAT package reviewed for one unit
Availability confirmedConfirmed by J&J Request current allocation and release terms · subject to prior sale
Email for Specs, Price & Availability
Jump to a section

Buying several transformers or reviewing an exact ratio?

For a multi-unit order, specify each electrical configuration, accepted condition and delivery phase. Start with the current equipment records, then request the identity, documents, allocation and quote scope for each proposed unit.

Surplus electrical transformers for sale

Surplus power transformers may be unused equipment from a canceled project or previously operated units. Compare surplus GSU and substation transformer offers by the individual nameplate, cooling-stage rating and condition; ownership history alone does not establish whether a unit has been energized.

Transformers for sale by voltage

Compare power transformers for sale for 69 kV, 115 kV, 138 kV, 230 kV, 345 kV and 500 kV system projects. Review each equipment record's exact winding voltages, MVA, condition and current allocation before requesting a quote.

Review the offer, condition and release basis

Current records separate J&J-confirmed availability, dated written offers, newly submitted inventory schedules and 2027 production positions. Stored surplus is not automatically used equipment, and future production is not ready-to-ship stock. Request current allocation, photos, matching records, inspection and complete loading, shipping and warranty terms through J&J.

Is the surplus transformer unused or previously operated?

Surplus describes why equipment is no longer needed; it does not define its operating history. A surplus unit can be unused, previously energized or rebuilt. Buyers looking for second-hand or pre-owned transformers should request that history explicitly, while a new/unused requirement needs a matching condition statement and preservation records.

How do surplus and second-hand transformer condition differ?

An unused surplus transformer may never have been energized. A second-hand transformer has prior service, while a rebuilt unit has a defined repair or rebuild history. Confirm each unit's actual operating, storage, preservation, testing and transport records; the advertised model or manufacture year alone does not establish condition.

Review an existing transformer against your requirement

An unused-surplus or previously operated transformer may be a supply option when its documented configuration and condition fit the project. J&J distinguishes represented information from records reviewed for the actual equipment.

  • Compare the public rating, voltage, quantity and represented condition.
  • Call or email to discuss availability, operating or storage history and the records held.
  • Confirm inspection options, accessories, shipping scope and commercial terms for the proposed unit.

What makes a transformer a replacement candidate?

A matching voltage ratio is the starting point. Compare the existing transformer and proposed replacement on the same rating basis before reserving equipment. Send the nameplate or one-line by email when available; an initial conversation can begin with MVA, voltages and your required date.

Replacement screening before a commercial offer
CompareWhat the project team needs to confirm
Capacity and coolingRequired MVA at each cooling stage, ambient conditions and operating duty—not only the highest rating.
Winding connectionsHigh, low and tertiary voltages; vector group, phase displacement, neutral and grounding requirements.
System performanceImpedance with its MVA base, tap range and controls, insulation levels, protection and fault-duty requirements.
Installation and scheduleTerminal arrangement, dimensions, accessories, inspection, loading, transport and the needed-on-site date.

What should a project team submit for a useful surplus-transformer search?

Start with the failed-unit nameplate or target specification and state which differences the project engineer may consider. At minimum, provide MVA or kVA, every winding voltage, intended duty, phase, frequency, site, destination, acceptable condition, and required date.

  • Electrical: MVA by cooling stage, ratio, maximum system voltage, BIL, impedance and basis, vector/phase displacement, neutral, taps, losses, harmonics, and fault-duty constraints.
  • Physical: terminals, dimensions, foundation limits, total and shipping weights, oil or gas shipping state, access, sound, ambient, altitude, seismic, wind, and environmental requirements.
  • Evidence: nameplate, final outline, schematics, certified tests, condition and storage records, maintenance and fluid data, photos, accessory list, and transport information.
  • Commercial: destination, needed-on-site date, inspection/test requirements, acceptable deviations, warranty expectations, origin restrictions, and purchasing entity.

What must be verified before a surplus transformer is quote-ready?

J&J seeks evidence for exact identity, seller ownership or representation authority, present condition, technical fit, included scope, location, inspection and test rights, logistics, warranty provider, price basis, payment terms, and current availability. Missing items stay visible as open items rather than being converted into claims.

Surplus transformer evidence gates
GatePreferred evidenceIf unresolved
IdentityLegible serial-specific nameplate reconciled to drawings and reportsCandidate remains preliminary
AuthorityOwner or documented representation path for the exact unitNo controlled-availability claim
Technical fitRequirement-versus-candidate schedule using final ratings and test valuesDeviation requires purchaser/engineer disposition
ConditionCurrent inspection, history, preservation, fluid/electrical tests as applicableCondition and work scope remain open
Commercial/logisticsWritten scope, location, shipping state, price, terms, warranty and milestonesNo delivered-price or schedule commitment

What does J&J return after screening the requirement?

When a responsible source and plausible technical match exist, J&J can return a focused candidate summary with the known ratings, evidence reviewed, open deviations, location and logistics status, commercial scope, and next diligence step. If the evidence is not ready, the result remains a supply lead rather than a quote-ready unit.

Public listings are represented opportunities, not reserved or guaranteed stock. Seller authority, serial identity, present condition, exact location, availability, price, included scope, and delivery require current written confirmation and remain subject to prior sale.

Use the buyer tools before comparing equipment

Estimate the load, review the candidate's condition records, and compare the complete quotation on the same basis. These resources help your project team identify missing information before accepting a transformer offer.

Buying a replacement or planning a spare?

Compare the offered transformer with the operating unit and the project specification. Keep the winding duty, cooling-stage ratings, technical deviations, inspection scope and delivery responsibilities beside the quoted price.

Buying this condition for step-down duty

For a new, unused, used, rebuilt or surplus step-down requirement, retain the offered unit's actual condition and evidence basis. Confirm the permitted operating direction, continuous capacity, winding connections, grounding, taps, test records and included equipment before accepting a match.

Choose the transformer duty before comparing sale offers

Describe the transformer you want to buy by actual source/output voltage, required MVA, power-flow duty, quantity, condition acceptance and delivery date. Step-down, substation, GSU, pad-mounted, dry-type and autotransformer inquiries remain separate technical matches within J&J's broader transformer supply coverage.

  • For used, surplus, rebuilt or unused equipment, compare the candidate's nameplate, drawings, available tests, storage history and written condition description.
  • State a requested manufacturer or model where necessary; branded equipment inquiries do not establish manufacturer authorization, matching stock or an approved substitute.

Common questions

Written quotes and supporting records control unit-specific ratings, availability, condition, price, and delivery.

Are surplus transformers always used?

Surplus power transformers may be unused equipment from a canceled project or previously operated units. Compare surplus GSU and substation transformer offers by the individual nameplate, cooling-stage rating and condition; ownership history alone does not establish whether a unit has been energized. Email tommy@jjtransformers.com or call Tommy Marco at 346-276-9540 for the exact equipment record, price and written availability.

Is unused surplus equipment the same as a new factory order?

No. An existing unused unit has its own manufacturing date, storage history, configuration and warranty terms. Review those records and the scope offered for the specific unit before comparing it with a new factory order.

Can I review transformer reports and arrange an inspection?

Email the listing reference and your requirement. J&J will confirm which records are available and discuss inspection arrangements and any commercial conditions directly. Public listings do not establish a completed inspection or transferable warranty.

How do I get prices, photos and technical documents?

Call Tommy Marco at 346-276-9540 or email tommy@jjtransformers.com. Specifications, reports, photos and pricing are shared directly after contact, according to the records available for the proposed unit. Availability remains subject to prior sale and written confirmation.

Does J&J publish every surplus transformer it can screen?

No. The public inventory is selective. Project teams can submit an exact requirement for screening against public records and current non-public owner-authorized sources.

Are all surplus transformers owned by J&J?

No blanket ownership claim is made. The written candidate summary or quote should state the ownership or representation basis for the exact unit.

Does surplus mean unused?

Not always. Surplus may refer to unused project equipment, while other opportunities may be used or reconditioned. The exact condition and evidence must be stated.

Can a surplus transformer shorten a project schedule?

Potentially, but only after identity, fit, condition, testing, missing scope, transport, site work, commercial terms, and current availability are confirmed.

Can I buy an unused transformer on a shorter schedule?

Possibly. Review the represented condition and evidence on the specific listing, then confirm serial identity, present condition, warranty provider, technical fit, scope, location, price, logistics, and written availability before relying on it.

What is the fastest way to request a private match?

Send the target or failed-unit nameplate, one-line, MVA, voltages, BIL, impedance, vector, taps, site, destination, condition preference, and needed-on-site date.

Can J&J evaluate a seller's surplus transformer?

J&J can review equipment submitted by email to tommy@jjtransformers.com when the direct owner, owner-employed asset team, or transfer-authorized EPC provides identity, ratings, condition, location, records, authority, and commercial expectations.

Can I request several transformers with different voltage ratios or MVA ratings?

Yes. Send quantity per configuration, winding voltages, continuous MVA, accepted condition and required delivery phase to Tommy. The quotation identifies the actual unit, documents, allocation and included scope for every position. Identical-unit and parallel-operation requirements need explicit review.

Call Email Sales