Two Westinghouse / GE Rebuilt 39.6/52.8/66 MVA Transformer Offers

Equipment location: USA. J&J is based in Sugar Land, Texas and serves projects nationwide.

Condition: Pre-owned / rebuilt; recorded valve leaks and broken gauge require present repair verification. Two rebuilt units offered. One supplied report shows 140.9 kV delta / 34.5 kV wye; resolve the nominal 138 kV offer description and verify recorded leak and gauge repairs. Email Tommy with reference JJ-WEST-GE-66-2 for specifications, price and current release timing. Listing information reviewed .

Availability & record date
Written equipment offerOffer received Request current allocation and release terms · subject to prior sale
Photos on requestAsk Tommy for photos & specs
Photo availability

Public photos are not shown for this listing. Ask J&J for a current photo set and the matching technical records.

Equipment summary

Specifications and scope

Unit IDJJ-WEST-GE-66-2
ManufacturerWestinghouse
Manufacturer basisWritten offer identifies Westinghouse manufacture and a GE Energy rebuild; supplied maintenance report covers one unit
Rating39.6/52.8/66 MVA represented; 66 MVA in one supplied report
Voltage / output140.9 kV Delta / 34.5 kV Wye in one report; offered as nominal 138/34.5 kV
Frequency60 Hz in the supplied report; confirm both units
Received offer date
Vector groupDelta–Wye in one supplied report; both nameplates and clock to confirm
TertiaryNot documented; confirm the complete winding arrangement
Quantity2 represented units; report reviewed for 1
AvailabilityOffered September 23, 2026; voltage, present condition and availability require written confirmation
Condition basisPre-owned / rebuilt; recorded valve leaks and broken gauge require present repair verification
Current locationUSA
Listing information reviewed

Technical values and record basis

Supplied nameplate and maintenance report for one unit in a two-unit offer; match the second unit separately and reconcile the rebuild dates.

PhasesThree-phase in the supplied report
CoolingOA / FA in the supplied report
Temperature rise65°C in the supplied report
Impedance and base7.2% reported; MVA base to confirm
Voltage discrepancyOne report states 140.9 kV delta / 34.5 kV wye; the offer calls the pair nominal 138/34.5 kV
Repair itemsRecorded bottom-valve oil leaks and broken gauge; present repair completion unverified
Remanufacture date discrepancyReviewed nameplate states March 2008; offer email claims a 2012 rebuild. Confirm the actual work history for each unit.
Nameplate impedance and base7.26% at 39.6 MVA on the reviewed plate; separate maintenance report rounds to 7.2%
Conductor on reviewed plateCopper
Insulation / BIL on reviewed plateHV 550 kV / LV 200 kV; verify both units

Details to confirm for this listing

  • Both final nameplates and exact voltage fit; rating stages and impedance bases
  • Current leak/gauge repairs, oil analysis, full tests, service history and transport scope

Technical highlights

  • The offer represents two Westinghouse transformers rebuilt by GE Energy, rated 39.6/52.8/66 MVA. One supplied nameplate states March 2008 remanufacture, conflicting with the email's 2012 rebuild claim; reconcile the rebuild history for each unit.
  • The offered nominal 138/34.5 kV description differs from the 140.9 kV delta / 34.5 kV wye nameplate fields in the supplied report for one unit. Resolve this before approving project duty; 138 kV is not presented as a verified nameplate rating.
  • The readable report covers one unit, not both. It records three-phase, 60 Hz, 66 MVA, OA/FA cooling, 65 C rise and 7.2% impedance; confirm the nameplate and rating basis for each unit.
  • Maintenance entries record bottom-valve oil leaks through March 2026 and a broken gauge in November 2025. Present repair completion and condition have not been verified.
  • A July 2025 dielectric result was recorded as unacceptable, followed by later acceptable readings. Obtain the complete history, current inspection and new tests appropriate to the purchase.
  • Request the second unit's individual nameplate, test and maintenance package. Historical service entries do not establish present operating status, readiness to energize or availability.

Evidence reviewed

Written offer identifies Westinghouse manufacture and a GE Energy rebuild; supplied maintenance report covers one unit

Records apply only to the stated unit or design basis.

Availability and terms

Offered September 23, 2026; voltage, present condition and availability require written confirmation

Ask for the current technical package, price, included accessories and delivery terms.

Confirm the purchase and delivery scope

Ask J&J to confirm the proposed unit’s allocation, price, inspection access, included accessories, loading and freight boundary, receiving arrangements, release schedule, deposit or reservation terms and any applicable warranty. Photos, matching records and inspection arrangements are coordinated through J&J.

Request written terms

Check this transformer against your project

Compare the complete winding arrangement and condition evidence before requesting a quote. A matching voltage ratio alone does not establish suitability.

For this listing’s photographs, reports, pricing and current status, call 346-276-9540 or email Tommy with unit ID JJ-WEST-GE-66-2.

Compare related equipment

Review the voltage-class guide

Need a different unit?

Send the exact requirement.

Include MVA or MW, voltage, quantity, site, and need-by date for a private match.