Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.
| Compare | 100 CAT G3520K 2.5 MW Gas GeneratorsJJ-GEN-CAT3520K | Two CAT 3516C 2000 kW 480V Diesel GeneratorsJJ-GEN-CAT3516C-2 |
|---|---|---|
| Manufacturer | Caterpillar | Caterpillar |
| Rating / output | 2,500 ekW / 3,125 kVA at 0.8 PF per unit; 250 MW total nameplate output | 2,000 kW / 2,500 kVA standby at 0.8 power factor on photographed unit |
| Voltage / winding arrangement | 480 V | 480 V, three-phase |
| Vector group | Not applicable; generator connection per technical package | Wye, series connection; six leads on photographed nameplate |
| Frequency | 60 Hz | 60 Hz on photographed unit |
| Cooling | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 100 units | 2 units |
| Technical details / open items | Caterpillar G3520K K-Series, 20-cylinder natural gas engines; 2,500 ekW / 3,125 kVA each at 0.8 power factor, 60 Hz, 480 V.; Skid-mounted generator sets supplied without individual enclosures. Five equipment buildings are specified, each housing 20 generator sets.; One Safety Power ecoCUBE SCR system per generator set. Emissions configuration and permit suitability are reviewed for the specific project location.; Balance of plant: two GE 13/115/230 kV step-up transformers, one 3,200 A load bank, two main switchgear lineups and ten sub-line lineups, plant controls and protection, and 20 chiller-cooler units.; The intermediate step-up from 480 V, medium-voltage collection, transformer MVA ratings and final one-line are established in the project engineering scope.; Installation, commissioning, testing and documentation are included within the agreed EPC scope. Site responsibilities, exclusions and warranty terms are set out in the definitive written agreement.; All 100 generator sets and supplied balance-of-plant equipment are specified for readiness within 90 days of deposit received in escrow. This is the equipment readiness milestone; the installation schedule follows site review.; Contact Tommy Marco for the technical package, inspection arrangements, project scope and commercial terms. | Two units offered by J&J on October 29, 2026. The repeated tag photos document one unit, rather than two distinct serial-number records.; Photographed Caterpillar nameplate: 3516C engine model; standby duty; 2,000 kW / 2,500 kVA at 0.8 power factor. This is a standby rating; no prime or continuous output is established by the supplied tag.; Electrical nameplate: 480 V, three-phase, 60 Hz, 3,007 A and 1,800 RPM; wye, series connection with six leads.; October 2016 manufacture is shown on the photographed generator-set nameplate. Confirm the second unit’s manufacture date, ratings, electrical configuration and matching records before allocation.; Class H insulation; frame 1625; rated ambient 40 °C and altitude 1,000 m. NEMA temperature rise 125 °C by resistance; UL maximum temperature rise 135 °C by resistance.; Excitation: 56 V and 4.6 A. The supplied tag also records the alternator reactance and time-constant values, available for the engineering review.; Caterpillar identifies the 3516C model family as diesel generator sets. No unit-specific emissions tier, emissions permit suitability, load-bank result, warranty, low-hour claim or refurbishment claim is established by these photos.; Contact Tommy Marco at 346-276-9540 or tommy@jjtransformers.com for unit pricing, hours, maintenance history, inspection and an itemized equipment and delivery scope. |
| Evidence reviewed | Current J&J G3520K package specification | J&J-supplied equipment and nameplate photos; detailed ratings verified on one photographed unit; quantity of two confirmed by J&J on October 29, 2026 |
| Technical value basis | Current J&J G3520K package specification | Technical values transcribed from the photographed Caterpillar generator-set nameplate. These values apply to the documented unit; obtain the second unit’s matching nameplate before final selection. |
| Details to confirm | Matching technical records, current condition, complete equipment scope and transport details | Second-unit nameplate, manufacture date, serial identity and matching electrical ratings; Operating hours, starts, service history and present operating condition for each unit; Inspection and load-bank test records; unit-specific emissions configuration and site requirements; Final included auxiliaries, controls, fuel equipment, removal, loading, freight, warranty and release terms |
| Represented condition | Brand new, unused; 2026 production | Pre-owned; pictured installed indoors; operating condition and service history to confirm |
| Technical records reviewed | 2026-10-23 | 2026-10-29 |
| Availability | Available; equipment ready within 90 days of deposit received in escrow; subject to prior sale | Two units available, confirmed by J&J October 29, 2026; subject to prior sale and written allocation |
| Availability last confirmed | 2026-10-23 | 2026-10-29 |
| Shipping estimate | Equipment readiness within 90 days of deposit received in escrow; transit and EPC schedule agreed separately | Removal, loading, freight and delivery schedule confirmed with quotation |
| Nameplate reviewed | Not recorded as reviewed; request it | Yes — request the unit package |
| Drawings reviewed | Not recorded as reviewed; request them | Not recorded as reviewed; request them |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Request more info | Request more info |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist