Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare88 MVA 230/34.5 kV WEG Power TransformerJJ-WEG-230-88167 MVA 230/34.5 kV Fortune Electric TransformerJJ-FORTUNE-230-167
ManufacturerWEGFortune Electric
Rating / output53/70.5/88 MVA; 18.55/24.675/30.8 MVA tertiary100/133/167 MVA; 35 MVA tertiary
Voltage / winding arrangement230/34.5 kV with 13.8 kV stabilizing delta tertiary230/34.5 kV with 13.3 kV buried-delta tertiary
Vector groupYNyn0d1YNyn0d1
Frequency60 Hz60 Hz
CoolingONAN / ONAF1 / ONAF2ONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JNot documented; confirm with J&J
Tap changerHV OLTC; 207–253 kV (±10%); 16 raise / 16 lower steps of 0.625%HV OLTC; 207–253 kV (±10%), design basis
Insulation / BILNot documented; confirm with J&JHV line 750 kV; HV neutral and LV 200 kV; tertiary 110 kV
Quantity represented1 nameplate-documented unit1 unit
Technical details / open itemsThree-phase, 60 Hz, ONAN/ONAF1/ONAF2, vector group YNyn0d1; 230 kV grounded-wye primary, 34.5 kV grounded-wye secondary, and 13.8 kV stabilizing delta tertiary; HV LTC represented at plus/minus 10% with 16 raise and 16 lower steps; 2020 manufacture shown on the reviewed nameplate drawingThree-phase, 60 Hz; ONAN/ONAF1/ONAF2 cooling; 65 C winding rise; Grounded-wye / grounded-wye / delta; vector group YNyn0d1; HV OLTC range 207-253 kV; 13.3 kV, 35 MVA buried-delta tertiary; Copper windings, Type II mineral oil; Nameplate drawing identifies suitability for step-up operation; final test results and impedance available subject to confirmation
Evidence reviewedSerial-specific nameplate drawing reviewedNameplate drawing reviewed
Technical value basisSupplied approval nameplate drawing; the impedance field is not completed.Supplied design nameplate and outline drawings; blank final values remain unconfirmed.
Details to confirmFinal tested impedance/base, all winding/bushing BIL levels and oil quantity; Matching factory tests, current preservation, final dimensions and complete accessoriesFinal tested impedance and base, manufacture year and final tap-switch specification; Final oil quantity, dimensions, tests, current preservation and complete accessories
Represented conditionBrand new, never used and never energized; 2020 nameplate reviewedBrand new, never used and never energized
Equipment locationUSAUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; nameplate drawing reviewed; subject to prior sale and written reconfirmationAvailable; subject to prior sale and written confirmation
Availability last confirmed2026-09-242026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageYes — request the unit package
Drawings reviewedYes — request matching unit drawingsYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales