| Compare | 25 Jenbacher J420E 1.5 MW 50 Hz GeneratorsJJ-J420-MULTI | 100 CAT G3520K 2.5 MW Gas GeneratorsJJ-GEN-CAT3520K |
|---|---|---|
| Manufacturer | INNIO Jenbacher | Caterpillar |
| Rating / output | Nominal 1.5 MW per unit | 2,500 ekW / 3,125 kVA at 0.8 PF per unit; 250 MW total nameplate output |
| Voltage / winding arrangement | 400 V line-to-line / 231 V line-to-neutral | 480 V |
| Vector group | Not applicable; generator connection per technical package | Not applicable; generator connection per technical package |
| Frequency | 50 Hz | 60 Hz |
| Cooling | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 25 units immediately available | 100 units |
| Technical details / open items | 25 units immediately available in the offered 50 Hz configuration.; Jenbacher J420E enclosed natural gas generator packages, nominal 1.5 MW each, 50 Hz, 400/231 V.; The units are offered in their existing 50 Hz configuration. Any frequency conversion is entirely the buyer's responsibility, arranged and paid for by the buyer. J&J does not perform or include conversion.; A buyer considering conversion must obtain an approved engineering scope for the exact engine, alternator, controls, auxiliaries and resulting output rating.; Generator breaker and connection point included per supplied specification. SCR is a project-specific optional addition.; Contact Tommy for pricing, matching nameplates, current photos, inspection and release terms. | Caterpillar G3520K K-Series, 20-cylinder natural gas engines; 2,500 ekW / 3,125 kVA each at 0.8 power factor, 60 Hz, 480 V.; Skid-mounted generator sets supplied without individual enclosures. Five equipment buildings are specified, each housing 20 generator sets.; One Safety Power ecoCUBE SCR system per generator set. Emissions configuration and permit suitability are reviewed for the specific project location.; Balance of plant: two GE 13/115/230 kV step-up transformers, one 3,200 A load bank, two main switchgear lineups and ten sub-line lineups, plant controls and protection, and 20 chiller-cooler units.; The intermediate step-up from 480 V, medium-voltage collection, transformer MVA ratings and final one-line are established in the project engineering scope.; Installation, commissioning, testing and documentation are included within the agreed EPC scope. Site responsibilities, exclusions and warranty terms are set out in the definitive written agreement.; All 100 generator sets and supplied balance-of-plant equipment are specified for readiness within 90 days of deposit received in escrow. This is the equipment readiness milestone; the installation schedule follows site review.; Contact Tommy Marco for the technical package, inspection arrangements, project scope and commercial terms. |
| Evidence reviewed | Supplied J420E package specification and current J&J allocation | Current J&J G3520K package specification |
| Technical value basis | Supplied J420E package specification and current J&J allocation | Current J&J G3520K package specification |
| Details to confirm | Matching technical records, current condition, complete equipment scope and transport details | Matching technical records, current condition, complete equipment scope and transport details |
| Represented condition | New, enclosed and sound-attenuated, per the supplied package specification | Brand new, unused; 2026 production |
| Technical records reviewed | 2026-10-23 | 2026-10-23 |
| Availability | 25 immediately available; subject to prior sale and written allocation | Available; equipment ready within 90 days of deposit received in escrow; subject to prior sale |
| Availability last confirmed | 2026-10-23 | 2026-10-23 |
| Shipping estimate | Request a written dispatch and delivery schedule | Equipment readiness within 90 days of deposit received in escrow; transit and EPC schedule agreed separately |
| Nameplate reviewed | Not recorded as reviewed; request it | Not recorded as reviewed; request it |
| Drawings reviewed | Not recorded as reviewed; request them | Not recorded as reviewed; request them |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Request more info | Request more info |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist