Compare10 Wärtsilä 9.4 MW Generator UnitsJJ-GEN-WARTSILA-94CAT 3516E 3000 kW Standby Diesel GeneratorsJJ-GEN-CAT3516E-8
ManufacturerWärtsiläCaterpillar
Rating / output9.4 MW per unit; 94 MW aggregate stated unit capacity for all 10 units3,000 kW / 3,333 kVA standby at 0.9 power factor on reviewed nameplate
Voltage / winding arrangementGenerator voltage confirmed for the selected unit and package480 V, three-phase
Vector groupNot applicable; generator and transformer connections reviewed separatelyWye series, six leads on reviewed nameplate
FrequencyInstalled frequency confirmed for the selected unit60 Hz
CoolingNot documented; confirm with J&JNot documented; confirm with J&J
Impedance and baseNot documented; confirm with J&JNot documented; confirm with J&J
Tap changerNot documented; confirm with J&JNot documented; confirm with J&J
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented10 units8 identified units in the technical package
Technical details / open itemsTen Wärtsilä / Wartsila 9.4 MW generating units offered through J&J.; 9.4 MW each × 10 units = 94 MW aggregate stated unit capacity; net site output depends on the equipment configuration, auxiliaries and operating conditions.; The exact engine model, fuel type, installed frequency, voltage, duty rating, hours and maintenance history are supplied with the technical package.; Ask about the required quantity, included generating equipment, inspection arrangements, unit pricing, loading and release schedule. Complete power plant scope is established separately in writing.Eight 3516E engine/product identities appear in the technical package, with machine-build dates from October through December 2024. The reviewed generator-set nameplate is dated February 2025.; Reviewed nameplate: 3,000 kW / 3,333 kVA, 0.9 PF, 480 V, three-phase, 60 Hz, 4,009 A and 1,800 RPM; wye series, six leads, Class H insulation.; Reviewed factory-order example: 3516E HPD, 3,000 ekW standby with fan, EMCP 4.2B controller, 5,000 A IEC busbar with top cable entry, AF81AVS radiator and dual electric starting.; That factory-order example specifies two 35 A battery chargers, no batteries ordered, no factory circuit breaker, non-UL-2200-listed package, no CSA selection and no seismic certification selection. Panel and decal selection is Portuguese. Match the actual order record to each selected unit.; Emissions records identify the 2024 engine family as EPA Emergency Stationary, constant speed. This is not a claim of prime/continuous duty or of suitability for a particular site's emissions permit.; The documented 3 MW rating is standby. A proposed lower output or duty change, including 2.75 MW operation, needs the selected-unit OEM/dealer rating and emissions review; no continuous rating or automatic conversion is promised.
Evidence reviewedEquipment availability supplied by J&J on October 26, 2026; matching technical records provided with the unit quotationJ&J technical package dated November 3, 2026: eight-unit build schedule, one reviewed factory-order record and one reviewed generator-set nameplate
Technical value basisEquipment availability supplied by J&J on October 26, 2026; matching technical records provided with the unit quotationReviewed factory-order example and nameplate in the November 3, 2026 J&J technical package; match selected-unit records
Details to confirmMatching technical records, current condition, complete equipment scope and transport detailsSelected-unit condition, hours, service records and allocation; Per-unit factory options and certification selections; Any proposed lower-output or duty change and site emissions-permit acceptance
Represented conditionUnit condition, operating hours and maintenance history confirmed with the technical packageFactory configuration documented; selected-unit condition, hours and service history supplied with the quotation
Technical records reviewed2026-10-262026-11-05
AvailabilityAvailable through J&J; subject to prior sale and written allocationEight-unit package documented November 3, 2026; current allocation and release schedule confirmed by quotation
Availability last confirmed2026-10-26Request current confirmation
Shipping estimateRequest a written dispatch and delivery schedulePreparation, loading, transit and site delivery scheduled for the selected units
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales