Your equipment shortlist
Compare equipment before you request it.
Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.
| Compare | 100 Used Cummins QSK60 G5 1.3 MW GeneratorsJJ-GEN-QSK60-USED | CAT 3516E 3000 kW Standby Diesel GeneratorsJJ-GEN-CAT3516E-8 |
|---|---|---|
| Manufacturer | Cummins | Caterpillar |
| Rating / output | 1.3 MW per unit; confirm the required frequency and duty in the unit schedule | 3,000 kW / 3,333 kVA standby at 0.9 power factor on reviewed nameplate |
| Voltage / winding arrangement | Unit-specific output voltage confirmed with quotation | 480 V, three-phase |
| Vector group | Not applicable; generator connection per technical package | Wye series, six leads on reviewed nameplate |
| Frequency | 50/60 Hz; required configuration confirmed per unit | 60 Hz |
| Cooling | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 100 units | 8 identified units in the technical package |
| Technical details / open items | 100 used Cummins QSK60 G5 units offered; 1.3 MW per unit and 50/60 Hz configurations as specified by J&J.; Every unit has over 7,500 operating hours. Exact hour-meter readings and service records are provided for the selected units.; $575,000 USD per unit, including shipping. Confirm the delivery destination and schedule in the written offer.; Confirm each unit's engine and alternator nameplates, installed frequency, voltage, duty rating, maintenance history and included accessories against the buyer's requirement.; This is a separate used-equipment offer from J&J's 25 brand-new QSK60 units. The new-package datasheet does not establish the used fleet's unit-specific condition or configuration. | Eight 3516E engine/product identities appear in the technical package, with machine-build dates from October through December 2024. The reviewed generator-set nameplate is dated February 2025.; Reviewed nameplate: 3,000 kW / 3,333 kVA, 0.9 PF, 480 V, three-phase, 60 Hz, 4,009 A and 1,800 RPM; wye series, six leads, Class H insulation.; Reviewed factory-order example: 3516E HPD, 3,000 ekW standby with fan, EMCP 4.2B controller, 5,000 A IEC busbar with top cable entry, AF81AVS radiator and dual electric starting.; That factory-order example specifies two 35 A battery chargers, no batteries ordered, no factory circuit breaker, non-UL-2200-listed package, no CSA selection and no seismic certification selection. Panel and decal selection is Portuguese. Match the actual order record to each selected unit.; Emissions records identify the 2024 engine family as EPA Emergency Stationary, constant speed. This is not a claim of prime/continuous duty or of suitability for a particular site's emissions permit.; The documented 3 MW rating is standby. A proposed lower output or duty change, including 2.75 MW operation, needs the selected-unit OEM/dealer rating and emissions review; no continuous rating or automatic conversion is promised. |
| Evidence reviewed | Current equipment information supplied by J&J | J&J technical package dated November 3, 2026: eight-unit build schedule, one reviewed factory-order record and one reviewed generator-set nameplate |
| Technical value basis | Current equipment information supplied by J&J | Reviewed factory-order example and nameplate in the November 3, 2026 J&J technical package; match selected-unit records |
| Details to confirm | Matching technical records, current condition, complete equipment scope and transport details | Selected-unit condition, hours, service records and allocation; Per-unit factory options and certification selections; Any proposed lower-output or duty change and site emissions-permit acceptance |
| Represented condition | Used; every unit has over 7,500 operating hours | Factory configuration documented; selected-unit condition, hours and service history supplied with the quotation |
| Technical records reviewed | 2026-10-23 | 2026-11-05 |
| Availability | Available; subject to prior sale and written allocation | Eight-unit package documented November 3, 2026; current allocation and release schedule confirmed by quotation |
| Availability last confirmed | 2026-10-23 | Request current confirmation |
| Shipping estimate | Shipping included in the $575,000 USD per-unit price; delivery schedule confirmed with quotation | Preparation, loading, transit and site delivery scheduled for the selected units |
| Nameplate reviewed | Not recorded as reviewed; request it | Yes — request the unit package |
| Drawings reviewed | Not recorded as reviewed; request them | Not recorded as reviewed; request them |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Request more info | Request more info |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist