Your equipment shortlist
Compare equipment before you request it.
Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.
| Compare | 25 New Cummins QSK60 1.3 MW Gas GeneratorsJJ-GEN-QSK60-NEW | 10 Wärtsilä 9.4 MW Generator UnitsJJ-GEN-WARTSILA-94 |
|---|---|---|
| Manufacturer | Cummins | Wärtsilä |
| Rating / output | 60 Hz: 1,300 kW / 1,625 kVA; 50 Hz: 1,120 kW / 1,400 kVA (approximately 1.1 MW), continuous | 9.4 MW per unit; 94 MW aggregate stated unit capacity for all 10 units |
| Voltage / winding arrangement | 50 Hz: 380-440 V; 60 Hz: 416-480 V | Generator voltage confirmed for the selected unit and package |
| Vector group | Not applicable; generator connection per technical package | Not applicable; generator and transformer connections reviewed separately |
| Frequency | 50/60 Hz; specify required configuration | Installed frequency confirmed for the selected unit |
| Cooling | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 25 units | 10 units |
| Technical details / open items | 25 brand-new units; separate from the 100-unit used QSK60 G5 offer.; Continuous output in the supplied datasheet: 1,300 kW / 1,625 kVA at 60 Hz; 1,120 kW / 1,400 kVA at 50 Hz (approximately 1.1 MW).; The datasheet identifies GQSK60-G5 for 50 Hz and GQSK60-G8 for 60 Hz. Specify the required frequency before ordering; these ratings describe the corresponding configurations.; Output voltage ranges: 380-440 V at 50 Hz and 416-480 V at 60 Hz. Engine speed: 1,500 RPM at 50 Hz and 1,800 RPM at 60 Hz.; V16 engine with Cummins MCM700 governor; PE734E brushless alternator, permanent-magnet excitation and Class H insulation.; Datasheet package includes a Schneider NW25 four-pole breaker rated 2,500 A and a containerized cooling arrangement. Final accessories and supplied configuration per quotation.; The lower container measures 6.06 m x 2.44 m x 2.59 m. Total wet package weight is 26,840 kg including the upper cooling container; confirm assembled and shipping dimensions for logistics.; Contact Tommy Marco for pricing, current photos, the complete technical package and delivery timing. | Ten Wärtsilä / Wartsila 9.4 MW generating units offered through J&J.; 9.4 MW each × 10 units = 94 MW aggregate stated unit capacity; net site output depends on the equipment configuration, auxiliaries and operating conditions.; The exact engine model, fuel type, installed frequency, voltage, duty rating, hours and maintenance history are supplied with the technical package.; Ask about the required quantity, included generating equipment, inspection arrangements, unit pricing, loading and release schedule. Complete power plant scope is established separately in writing. |
| Evidence reviewed | Supplied QSK60 Surf MCPD datasheet and current J&J equipment schedule | Equipment availability supplied by J&J on October 26, 2026; matching technical records provided with the unit quotation |
| Technical value basis | Supplied QSK60 Surf MCPD datasheet and current J&J equipment schedule | Equipment availability supplied by J&J on October 26, 2026; matching technical records provided with the unit quotation |
| Details to confirm | Matching technical records, current condition, complete equipment scope and transport details | Matching technical records, current condition, complete equipment scope and transport details |
| Represented condition | Brand new | Unit condition, operating hours and maintenance history confirmed with the technical package |
| Technical records reviewed | 2026-10-23 | 2026-10-26 |
| Availability | 25 brand-new units offered; allocation and delivery schedule per quotation; subject to prior sale | Available through J&J; subject to prior sale and written allocation |
| Availability last confirmed | 2026-10-23 | 2026-10-26 |
| Shipping estimate | Request a written dispatch and delivery schedule | Request a written dispatch and delivery schedule |
| Nameplate reviewed | Not recorded as reviewed; request it | Not recorded as reviewed; request it |
| Drawings reviewed | Not recorded as reviewed; request them | Not recorded as reviewed; request them |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Request more info | Request more info |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist