Your equipment shortlist
Compare equipment before you request it.
Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.
| Compare | 25 New Cummins QSK60 1.3 MW Gas GeneratorsJJ-GEN-QSK60-NEW | Two CAT 3516C 2000 kW 480V Diesel GeneratorsJJ-GEN-CAT3516C-2 |
|---|---|---|
| Manufacturer | Cummins | Caterpillar |
| Rating / output | 60 Hz: 1,300 kW / 1,625 kVA; 50 Hz: 1,120 kW / 1,400 kVA (approximately 1.1 MW), continuous | 2,000 kW / 2,500 kVA standby at 0.8 power factor on photographed unit |
| Voltage / winding arrangement | 50 Hz: 380-440 V; 60 Hz: 416-480 V | 480 V, three-phase |
| Vector group | Not applicable; generator connection per technical package | Wye, series connection; six leads on photographed nameplate |
| Frequency | 50/60 Hz; specify required configuration | 60 Hz on photographed unit |
| Cooling | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 25 units | 2 units |
| Technical details / open items | 25 brand-new units; separate from the 100-unit used QSK60 G5 offer.; Continuous output in the supplied datasheet: 1,300 kW / 1,625 kVA at 60 Hz; 1,120 kW / 1,400 kVA at 50 Hz (approximately 1.1 MW).; The datasheet identifies GQSK60-G5 for 50 Hz and GQSK60-G8 for 60 Hz. Specify the required frequency before ordering; these ratings describe the corresponding configurations.; Output voltage ranges: 380-440 V at 50 Hz and 416-480 V at 60 Hz. Engine speed: 1,500 RPM at 50 Hz and 1,800 RPM at 60 Hz.; V16 engine with Cummins MCM700 governor; PE734E brushless alternator, permanent-magnet excitation and Class H insulation.; Datasheet package includes a Schneider NW25 four-pole breaker rated 2,500 A and a containerized cooling arrangement. Final accessories and supplied configuration per quotation.; The lower container measures 6.06 m x 2.44 m x 2.59 m. Total wet package weight is 26,840 kg including the upper cooling container; confirm assembled and shipping dimensions for logistics.; Contact Tommy Marco for pricing, current photos, the complete technical package and delivery timing. | Two units offered by J&J on October 29, 2026. The repeated tag photos document one unit, rather than two distinct serial-number records.; Photographed Caterpillar nameplate: 3516C engine model; standby duty; 2,000 kW / 2,500 kVA at 0.8 power factor. This is a standby rating; no prime or continuous output is established by the supplied tag.; Electrical nameplate: 480 V, three-phase, 60 Hz, 3,007 A and 1,800 RPM; wye, series connection with six leads.; October 2016 manufacture is shown on the photographed generator-set nameplate. Confirm the second unit’s manufacture date, ratings, electrical configuration and matching records before allocation.; Class H insulation; frame 1625; rated ambient 40 °C and altitude 1,000 m. NEMA temperature rise 125 °C by resistance; UL maximum temperature rise 135 °C by resistance.; Excitation: 56 V and 4.6 A. The supplied tag also records the alternator reactance and time-constant values, available for the engineering review.; Caterpillar identifies the 3516C model family as diesel generator sets. No unit-specific emissions tier, emissions permit suitability, load-bank result, warranty, low-hour claim or refurbishment claim is established by these photos.; Contact Tommy Marco at 346-276-9540 or tommy@jjtransformers.com for unit pricing, hours, maintenance history, inspection and an itemized equipment and delivery scope. |
| Evidence reviewed | Supplied QSK60 Surf MCPD datasheet and current J&J equipment schedule | J&J-supplied equipment and nameplate photos; detailed ratings verified on one photographed unit; quantity of two confirmed by J&J on October 29, 2026 |
| Technical value basis | Supplied QSK60 Surf MCPD datasheet and current J&J equipment schedule | Technical values transcribed from the photographed Caterpillar generator-set nameplate. These values apply to the documented unit; obtain the second unit’s matching nameplate before final selection. |
| Details to confirm | Matching technical records, current condition, complete equipment scope and transport details | Second-unit nameplate, manufacture date, serial identity and matching electrical ratings; Operating hours, starts, service history and present operating condition for each unit; Inspection and load-bank test records; unit-specific emissions configuration and site requirements; Final included auxiliaries, controls, fuel equipment, removal, loading, freight, warranty and release terms |
| Represented condition | Brand new | Pre-owned; pictured installed indoors; operating condition and service history to confirm |
| Technical records reviewed | 2026-10-23 | 2026-10-29 |
| Availability | 25 brand-new units offered; allocation and delivery schedule per quotation; subject to prior sale | Two units available, confirmed by J&J October 29, 2026; subject to prior sale and written allocation |
| Availability last confirmed | 2026-10-23 | 2026-10-29 |
| Shipping estimate | Request a written dispatch and delivery schedule | Removal, loading, freight and delivery schedule confirmed with quotation |
| Nameplate reviewed | Not recorded as reviewed; request it | Yes — request the unit package |
| Drawings reviewed | Not recorded as reviewed; request them | Not recorded as reviewed; request them |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Request more info | Request more info |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist