Your equipment shortlist
Compare equipment before you request it.
Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.
| Compare | 100 CAT G3520K 2.5 MW Gas GeneratorsJJ-GEN-CAT3520K | 25 New Cummins QSK60 1.3 MW Gas GeneratorsJJ-GEN-QSK60-NEW |
|---|---|---|
| Manufacturer | Caterpillar | Cummins |
| Rating / output | 2,500 ekW / 3,125 kVA at 0.8 PF per unit; 250 MW total nameplate output | 60 Hz: 1,300 kW / 1,625 kVA; 50 Hz: 1,120 kW / 1,400 kVA (approximately 1.1 MW), continuous |
| Voltage / winding arrangement | 480 V | 50 Hz: 380-440 V; 60 Hz: 416-480 V |
| Vector group | Not applicable; generator connection per technical package | Not applicable; generator connection per technical package |
| Frequency | 60 Hz | 50/60 Hz; specify required configuration |
| Cooling | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 100 units | 25 units |
| Technical details / open items | Caterpillar G3520K K-Series, 20-cylinder natural gas engines; 2,500 ekW / 3,125 kVA each at 0.8 power factor, 60 Hz, 480 V.; Skid-mounted generator sets supplied without individual enclosures. Five equipment buildings are specified, each housing 20 generator sets.; One Safety Power ecoCUBE SCR system per generator set. Emissions configuration and permit suitability are reviewed for the specific project location.; Balance of plant: two GE 13/115/230 kV step-up transformers, one 3,200 A load bank, two main switchgear lineups and ten sub-line lineups, plant controls and protection, and 20 chiller-cooler units.; The intermediate step-up from 480 V, medium-voltage collection, transformer MVA ratings and final one-line are established in the project engineering scope.; Installation, commissioning, testing and documentation are included within the agreed EPC scope. Site responsibilities, exclusions and warranty terms are set out in the definitive written agreement.; All 100 generator sets and supplied balance-of-plant equipment are specified for readiness within 90 days of deposit received in escrow. This is the equipment readiness milestone; the installation schedule follows site review.; Contact Tommy Marco for the technical package, inspection arrangements, project scope and commercial terms. | 25 brand-new units; separate from the 100-unit used QSK60 G5 offer.; Continuous output in the supplied datasheet: 1,300 kW / 1,625 kVA at 60 Hz; 1,120 kW / 1,400 kVA at 50 Hz (approximately 1.1 MW).; The datasheet identifies GQSK60-G5 for 50 Hz and GQSK60-G8 for 60 Hz. Specify the required frequency before ordering; these ratings describe the corresponding configurations.; Output voltage ranges: 380-440 V at 50 Hz and 416-480 V at 60 Hz. Engine speed: 1,500 RPM at 50 Hz and 1,800 RPM at 60 Hz.; V16 engine with Cummins MCM700 governor; PE734E brushless alternator, permanent-magnet excitation and Class H insulation.; Datasheet package includes a Schneider NW25 four-pole breaker rated 2,500 A and a containerized cooling arrangement. Final accessories and supplied configuration per quotation.; The lower container measures 6.06 m x 2.44 m x 2.59 m. Total wet package weight is 26,840 kg including the upper cooling container; confirm assembled and shipping dimensions for logistics.; Contact Tommy Marco for pricing, current photos, the complete technical package and delivery timing. |
| Evidence reviewed | Current J&J G3520K package specification | Supplied QSK60 Surf MCPD datasheet and current J&J equipment schedule |
| Technical value basis | Current J&J G3520K package specification | Supplied QSK60 Surf MCPD datasheet and current J&J equipment schedule |
| Details to confirm | Matching technical records, current condition, complete equipment scope and transport details | Matching technical records, current condition, complete equipment scope and transport details |
| Represented condition | Brand new, unused; 2026 production | Brand new |
| Technical records reviewed | 2026-10-23 | 2026-10-23 |
| Availability | Available; equipment ready within 90 days of deposit received in escrow; subject to prior sale | 25 brand-new units offered; allocation and delivery schedule per quotation; subject to prior sale |
| Availability last confirmed | 2026-10-23 | 2026-10-23 |
| Shipping estimate | Equipment readiness within 90 days of deposit received in escrow; transit and EPC schedule agreed separately | Request a written dispatch and delivery schedule |
| Nameplate reviewed | Not recorded as reviewed; request it | Not recorded as reviewed; request it |
| Drawings reviewed | Not recorded as reviewed; request them | Not recorded as reviewed; request them |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Request more info | Request more info |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist