Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare112 MVA-Class ABB 230/115/69 kV AutotransformerJJ-ABB-AUTO-112167 MVA 230/34.5 kV Fortune Electric TransformerJJ-FORTUNE-230-167
ManufacturerABBFortune Electric
Rating / output60/80/100 MVA at 55 C; 67.2/89.6/112 MVA at 65 C100/133/167 MVA; 35 MVA tertiary
Voltage / winding arrangement230 kV to reconnectable 115 or 69 kV with 13.5 kV delta tertiary230/34.5 kV with 13.3 kV buried-delta tertiary
Vector groupWye autotransformer / Delta tertiary; clock to confirmYNyn0d1
Frequency60 Hz60 Hz
CoolingOA / FA1 / FA2ONAN / ONAF1 / ONAF2
Impedance and base13.2% at 60 MVA, 230/69 kV; 7.4% at 60 MVA, 230/115 kVNot documented; confirm with J&J
Tap changerNot documented; confirm with J&JHV OLTC; 207–253 kV (±10%), design basis
Insulation / BILNot documented; confirm with J&JHV line 750 kV; HV neutral and LV 200 kV; tertiary 110 kV
Quantity represented1 nameplate-documented opportunity; available quantity to confirm1 unit
Technical details / open itemsThree-phase, 60 Hz, copper-wound ABB autotransformer; Reconnectable common winding for 69 kV or 115 kV service; 13.5 kV delta tertiary; Nameplate impedance: 13.2% on a 60 MVA, 230/69 kV base; 7.4% on a 60 MVA, 230/115 kV base; Complete matching nameplate records and the technical package are shared through J&JThree-phase, 60 Hz; ONAN/ONAF1/ONAF2 cooling; 65 C winding rise; Grounded-wye / grounded-wye / delta; vector group YNyn0d1; HV OLTC range 207-253 kV; 13.3 kV, 35 MVA buried-delta tertiary; Copper windings, Type II mineral oil; Nameplate drawing identifies suitability for step-up operation; final test results and impedance available subject to confirmation
Evidence reviewedSerial-specific nameplate photograph reviewedNameplate drawing reviewed
Technical value basisSupplied individual nameplate photograph; reconnection and tap arrangements require engineering review.Supplied design nameplate and outline drawings; blank final values remain unconfirmed.
Details to confirmSelected voltage reconnection, tertiary rating, insulation levels and current quantity; Complete tests, current preservation, accessory scope and transport dimensions/weightsFinal tested impedance and base, manufacture year and final tap-switch specification; Final oil quantity, dimensions, tests, current preservation and complete accessories
Represented conditionBrand new, never used and never energizedBrand new, never used and never energized
Equipment locationUSAUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; nameplate reviewed; quantity and delivery terms confirmed with the quotation; subject to prior saleAvailable; subject to prior sale and written confirmation
Availability last confirmed2026-09-242026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales