Identify the complete MV breaker before requesting a price
For a replacement, send the nameplate and existing switchgear or cubicle identification along with the required quantity. For a new project, send the specified voltage class, continuous current, interrupting duty, control power, mechanism and construction from the equipment schedule.
| Input | Confirm in the request |
|---|---|
| Device identity | Manufacturer, exact model, cubicle or lineup type and applicable drawings |
| Electrical duty | Rated voltage, continuous current, frequency, interrupting rating and project test requirements |
| Mechanism and controls | Operating mechanism, control supply, trip/close coils, auxiliary contacts and interlocks |
| Installed interfaces | Fixed or draw-out arrangement, dimensions, primary/secondary contacts and OEM compatibility |
| Commercial scope | New or acceptable condition, device count, spares, test records, warranty, destination and dates |
Vacuum breakers, complete devices and replacement compatibility
A vacuum interrupter, a complete vacuum circuit breaker and a breaker fitted to a specific switchgear cell are different supply scopes. Identify which item is required. A similar current rating or physical appearance does not establish that a replacement fits the installed cubicle or protection arrangement.
Order project quantities and spare sets by delivery phase
List operating devices and spares separately by model, ratings and controls. For several lineups, keep common designs visible and identify any different relay, control-power or cubicle requirement. J&J can review the device schedule alongside transformers and the rest of the distribution package.
Nine-week OEM delivery target and fast-release inventory
J&J targets nine weeks for qualifying new OEM equipment, including pad-mounted and dry-type transformers from 500 to 10,000 kVA, switchgear and breakers. The target includes manufacturing, agreed factory testing and shipping to the quoted destination after PO, approved drawings and production release. The factory confirms the configuration, quantity, production slot and site-arrival date in the written quotation. Large high-voltage power transformers have a separate unit-specific release and delivery schedule.
- OEM nine-week target, production release and delivered scope
- Existing transformer and power-equipment opportunities
| Supply route | Equipment scope | Delivery basis |
|---|---|---|
| Existing equipment | Documented new/unused, surplus, used or rebuilt transformer opportunities | Confirm the actual unit, allocation, inspection, preparation and transport before accepting the arrival date |
| New OEM programme | 500-10,000 kVA padmount and dry-type requirements, switchgear, breakers and quoted related equipment | Target nine weeks for qualifying configurations; factory slot, quantity and destination confirmed in the quotation |
| Large high-voltage transformers | High-MVA substation and GSU units, replacements and manufacturing positions | Individual written schedule; the nine-week distribution-equipment target does not set the schedule for a large power transformer |
Email a medium-voltage circuit-breaker RFQ
Email Tommy Marco at tommy@jjtransformers.com or call 346-276-9540. A short email or your existing equipment schedule is enough to start; attach the one-line or specification if available.
- Device model or project specification and required condition
- Voltage, continuous current, interrupting duty, frequency and control power
- Nameplate or cubicle photographs for a replacement
- Installed-device quantity, spare quantity, site and required arrival date
Common questions
Written quotes and supporting records control unit-specific ratings, availability, condition, price, and delivery.
Can J&J quote medium-voltage vacuum circuit breakers?
Yes. Send the exact device or project specification, voltage, continuous current, interrupting rating, control power, quantity and required date. Product selection and included scope are confirmed in the quotation.
Can I buy replacement breakers for existing switchgear?
J&J accepts replacement requests. Provide the installed breaker and cubicle identification, drawings, ratings and photographs so model-specific compatibility can be reviewed before an offer is accepted.
Can I request bulk circuit breakers and spare sets?
Yes. Group devices by identical model, ratings and controls, then identify operating and spare quantities for each phase. Send the related lineup schedule if the breakers are part of a larger package.
Are medium-voltage and low-voltage circuit breakers interchangeable?
No. They are selected for different electrical systems and installed interfaces. Confirm the exact voltage class, duty, construction and model-specific compatibility for the equipment being supplied.
Is a nine-week breaker delivery target available?
Ask about the nine-week target for qualifying new OEM equipment. Exact model, quantity, factory allocation, tests and destination must be confirmed. Legacy, retrofit and special devices have their own quoted availability.
