Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare88 MVA 230/34.5 kV WEG Power TransformerJJ-WEG-230-88ILJIN 167 MVA 230/34.5 kV New / Unused TransformerJJ-ILJIN-230-167
ManufacturerWEGILJIN Electric
Rating / output53/70.5/88 MVA; 18.55/24.675/30.8 MVA tertiary100/133/167 MVA
Voltage / winding arrangement230/34.5 kV with 13.8 kV stabilizing delta tertiary230/34.5 kV; tertiary voltage to confirm
Vector groupYNyn0d1YNyn0+d represented; tertiary clock to confirm
Frequency60 HzNot documented; confirm with J&J
CoolingONAN / ONAF1 / ONAF2Not documented; confirm with J&J
Impedance and baseNot documented; confirm with J&JNot documented; confirm with J&J
Tap changerHV OLTC; 207–253 kV (±10%); 16 raise / 16 lower steps of 0.625%Not documented; confirm with J&J
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented1 nameplate-documented unit1 represented unit
Technical details / open itemsThree-phase, 60 Hz, ONAN/ONAF1/ONAF2, vector group YNyn0d1; 230 kV grounded-wye primary, 34.5 kV grounded-wye secondary, and 13.8 kV stabilizing delta tertiary; HV LTC represented at plus/minus 10% with 16 raise and 16 lower steps; 2020 manufacture shown on the reviewed nameplate drawingThe individual August offer expressly identifies this ILJIN option as new/unused and never energized; that offer was forwarded again September 30, 2026.; A separate September 30 equipment table repeats 100/133/167 MVA and 230/34.5 kV. Dispatch location and allocation require current confirmation through J&J.; The supplied vector description is YNyn0+d. Obtain the individual nameplate, tertiary rating and voltage, vector clock, frequency, cooling stages and test records before duty approval.; Confirm preservation and storage history, actual warranty provider and transferable written coverage, loading and shipping terms with the quotation.; This ILJIN offer is distinct from the separately listed Fortune Electric 167 MVA transformer; no additional Fortune unit is implied.
Evidence reviewedSerial-specific nameplate drawing reviewedIndividual written offer, repeated in a September 30 equipment listing
Technical value basisSupplied approval nameplate drawing; the impedance field is not completed.Received written equipment offer; individual technical records require review.
Details to confirmFinal tested impedance/base, all winding/bushing BIL levels and oil quantity; Matching factory tests, current preservation, final dimensions and complete accessoriesIndividual nameplate, frequency, cooling/rise, tertiary duty and vector clock; Impedance/base, BIL, taps, copper/fluid specification, factory tests, preservation and transport scope
Represented conditionBrand new, never used and never energized; 2020 nameplate reviewedNew / unused and never energized, as explicitly represented in the offer
Equipment locationUSAInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; nameplate drawing reviewed; subject to prior sale and written reconfirmationListed in received September 30, 2026 offers; current allocation, condition and dispatch timing require written confirmation
Availability last confirmed2026-09-24Request current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageNot recorded as reviewed; request it
Drawings reviewedYes — request matching unit drawingsNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist