Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare7 TSEA 266 MVA 345/34.5 kV TransformersJJ-TSEA-345-266-7180 MVA 345/34.5 kV Georgia TransformerJJ-TX-003
ManufacturerTSEA energiaGeorgia Transformer
Rating / output160/213/266 MVA108/144/180 MVA; 37.8/50.4/63 MVA tertiary
Voltage / winding arrangement345/34.5 kV with 13.8 kV no-load delta tertiary345/34.5 kV with 12 kV buried-delta tertiary
Vector groupYNyn(d1), as stated in the design packageYNyn0+d1
Frequency60 HzNot documented; confirm with J&J
CoolingNot documented; confirm with J&JNot documented; confirm with J&J
Impedance and baseNot documented; confirm with J&JNot documented; confirm with J&J
Tap changerNot documented; confirm with J&JNot documented; confirm with J&J
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented7 units1 documented unit
Technical details / open items7 units at 266 MVA maximum; the separate 226 MVA group contains 12 units, for 19 total 345 kV units.; Cooling ratings: ONAN 160 MVA / ONAF1 213 MVA / ONAF2 266 MVA.; Design impedance: 8.5% at a 160 MVA base. HV/LV BIL: 1,175/200 kV.; Three-phase, 60 Hz; copper windings, mineral oil and 65 °C temperature rise.; HV on-load tap changer: ±10% in 0.625% steps; grounded-wye high- and low-voltage windings.; 13.8 kV delta tertiary shown as no load in the design drawings; external load duty requires OEM approval.; Possible modifications are available for engineering review. Feasibility, approved configuration, cost and delivery impact require OEM confirmation before order acceptance.; Quantities reflect the current J&J portfolio allocation. Request individual unit schedules, approved drawings, final nameplates, factory tests and the included shipping, commissioning and warranty scope with your quotation.ONAN/ONAF1/ONAF2, 60 Hz, three-phase, vector group YNyn0+d1; Measured H-X impedance: 6.99% on a 108 MVA base; Factory test report concludes results were within technical tolerances
Evidence reviewedReviewed TSEA design drawings and performance data; portfolio quantities updated by J&J on October 16, 2026Serial-specific approval drawings and FAT report reviewed
Technical value basisReviewed TSEA design drawings and offered performance data. Values describe the documented design; final unit-specific nameplates and factory test results are supplied with the approved technical package.Serial-specific approval drawings and FAT report reviewed
Details to confirmIndividual unit allocation, production and delivery schedule, approved drawings and final nameplate; OEM-approved modification scope and final winding/vector configuration; Final factory test reports, included accessories, warranty and certified transport dimensions/weightsMatching technical records, current condition, complete equipment scope and transport details
Represented conditionFactory manufacturing allocation; completion pendingBrand new, never used and never energized; factory acceptance tested September 2024
Equipment locationDispatch location confirmed with quotationUSA
Technical records reviewed2026-10-162026-10-08
AvailabilityProduction allocation offered through J&J; subject to prior sale and written release termsAvailable for sale — confirmed by J&J October 8, 2026; quotation and release terms on request
Availability last confirmedRequest current confirmation2026-10-08
Shipping estimate2027 production; delivery schedule confirmed by unit and projectRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itNot recorded as reviewed; request it
Drawings reviewedYes — request matching unit drawingsYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist