Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare105 MVA 161/34.5 kV Siemens Energy TransformerJJ-SIEMENS-161-105300 MVA 138/34.5 kV Georgia TransformerJJ-TX-001
ManufacturerSiemens EnergyGeorgia Transformer
Rating / output63/84/105 MVA180/240/300 MVA; 63/84/105 MVA tertiary
Voltage / winding arrangement161/34.5 kV with 13.8 kV tertiary138/34.5 kV with 12 kV buried-delta tertiary
Vector groupNot stated in supplied recordsYNyn0+d1
Frequency60 HzNot documented; confirm with J&J
CoolingONAN / ONAF1 / ONAF2Not documented; confirm with J&J
Impedance and baseH–X: 9.25% at 63 MVA; 12.34% at 84 MVA; 15.42% at 105 MVANot documented; confirm with J&J
Tap changerHV OLTC; 144.9–177.1 kV (±10%); ±8 steps of 1.25%Not documented; confirm with J&J
Insulation / BILHV line 650 kV; HV neutral and LV 200 kV; tertiary 110 kVNot documented; confirm with J&J
Quantity represented1 nameplate-documented unit1 documented unit
Technical details / open items2022 manufacture shown on nameplate; three-phase, 60 Hz, copper windings; ONAN/ONAF1/ONAF2 cooling and approximately 144.9-177.1 kV HV OLTC range; Nameplate identifies 34.5 kV low-side and 13.8 kV additional winding; Supplied equipment photo shown; request the connection diagram, complete matching records and preservation history through J&JONAN/ONAF/ONAF, 60 Hz, three-phase, vector group YNyn0+d1; Measured 138/34.5 kV impedance: 9.67% on a 180 MVA base; Copper windings, conservator system, Type II mineral oil, and HV OLTC
Evidence reviewedSerial-specific nameplate photograph reviewedSerial-specific nameplate reviewed
Technical value basisSupplied individual nameplate photograph; verify the winding diagram and current preservation.Serial-specific nameplate reviewed
Details to confirmComplete winding connection/clock diagram and tertiary MVA duty; Current preservation, matching tests, dimensions and accessory completenessMatching technical records, current condition, complete equipment scope and transport details
Represented conditionBrand new, never used and never energized; 2022 nameplate reviewedBrand new, never used and never energized; 2020 nameplate reviewed
Equipment locationUSAUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; nameplate reviewed; subject to prior sale and written reconfirmationAvailable for sale — confirmed by J&J October 8, 2026; quotation and release terms on request
Availability last confirmed2026-09-242026-10-08
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales