Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare105 MVA 161/34.5 kV Siemens Energy TransformerJJ-SIEMENS-161-105Royal SMIT 525/69 kV Transformers — 3 AvailableJJ-SMIT-525-3
ManufacturerSiemens EnergyRoyal SMIT
Rating / output63/84/105 MVA240/320/400 MVA; 250 MVA maximum step-down; 90 MVA tertiary
Voltage / winding arrangement161/34.5 kV with 13.8 kV tertiary525/69 kV with 13.7 kV buried-delta tertiary
Vector groupNot stated in supplied recordsYNyn0(d1) — Wye–Wye / buried Delta
Frequency60 Hz60 Hz
CoolingONAN / ONAF1 / ONAF2ONAN / ONAF / ONAF
Impedance and baseH–X: 9.25% at 63 MVA; 12.34% at 84 MVA; 15.42% at 105 MVAH–X: 12.90% at 240 MVA, 525/69 kV, 85°C
Tap changerHV OLTC; 144.9–177.1 kV (±10%); ±8 steps of 1.25%HV OLTC; 472.5–577.5 kV (±10%); 16 raise / 16 lower steps of 0.625%
Insulation / BILHV line 650 kV; HV neutral and LV 200 kV; tertiary 110 kVHV winding 1550 kV / bushing 1675 kV; LV 350 kV; tertiary 150 kV
Quantity represented1 nameplate-documented unit3 units
Technical details / open items2022 manufacture shown on nameplate; three-phase, 60 Hz, copper windings; ONAN/ONAF1/ONAF2 cooling and approximately 144.9-177.1 kV HV OLTC range; Nameplate identifies 34.5 kV low-side and 13.8 kV additional winding; Supplied equipment photo shown; request the connection diagram, complete matching records and preservation history through J&JThree units offered for allocation; availability and 4–8 week shipping schedule confirmed by J&J on October 1, 2026.; Nameplate rating: 240/320/400 MVA with ONAN/ONAF/ONAF cooling. Maximum stated duty: 400 MVA step-up or 250 MVA step-down.; Three-phase, 60 Hz; 525 kV grounded-wye high side, 69 kV wye low side, and 13.7 kV buried-delta tertiary rated 90 MVA.; Copper windings; MR on-load tap changer; HV tap range 472.5–577.5 kV (±10%).; HV BIL: 1550 kV winding / 1675 kV bushing. LV BIL: 350 kV.; Nameplate H-X impedance: 12.90% at 240 MVA base, 525/69 kV, 85°C.; Supplied 2022 factory acceptance test report records Passed for the documented unit. Nameplate, outline drawing and test report available through J&J; match the records to all three units before purchase.
Evidence reviewedSerial-specific nameplate photograph reviewedSupplied nameplate, outline drawing and factory acceptance test report
Technical value basisSupplied individual nameplate photograph; verify the winding diagram and current preservation.Supplied nameplate for one documented unit; match the complete package to each of the three offered units.
Details to confirmComplete winding connection/clock diagram and tertiary MVA duty; Current preservation, matching tests, dimensions and accessory completenessMatching records for each offered unit, current condition, included accessories and transport scope; Unit-specific factory tests, present preservation and the step-down duty limit
Represented conditionBrand new, never used and never energized; 2022 nameplate reviewed2022 manufacture shown in supplied nameplate; condition and service history confirmed with quotation
Equipment locationUSAInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; nameplate reviewed; subject to prior sale and written reconfirmationImmediately available; estimated 4–8 weeks to ship; subject to prior sale
Availability last confirmed2026-09-242026-10-01
Shipping estimateRequest a written dispatch and delivery schedule4–8 weeks to ship
Nameplate reviewedYes — request the unit packageYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist