Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare71.2 MVA Prolec GE 240/120-13.8 kV GSUJJ-PGE-240-71Royal SMIT 525/69 kV Transformers — 3 AvailableJJ-SMIT-525-3
ManufacturerProlec GERoyal SMIT
Rating / output42.7/57/71.2 MVA at 60 Hz240/320/400 MVA; 250 MVA maximum step-down; 90 MVA tertiary
Voltage / winding arrangement240/120 kV grounded-wye dual-voltage to 13.8 kV delta525/69 kV with 13.7 kV buried-delta tertiary
Vector groupGrounded Wye–Delta; clock to confirmYNyn0(d1) — Wye–Wye / buried Delta
Frequency60 Hz60 Hz
CoolingONAN / ONAF / ONAFONAN / ONAF / ONAF
Impedance and baseNot documented; confirm with J&JH–X: 12.90% at 240 MVA, 525/69 kV, 85°C
Tap changerDual-voltage HV DETC; confirm series/parallel reconnection and the complete 11-position tap tableHV OLTC; 472.5–577.5 kV (±10%); 16 raise / 16 lower steps of 0.625%
Insulation / BILHV winding: 900 kV series / 650 kV parallel; HV bushings 900 kV; LV 110 kV; HV neutral 250 kVHV winding 1550 kV / bushing 1675 kV; LV 350 kV; tertiary 150 kV
Quantity represented1 documented unit3 units
Technical details / open itemsGenerator step-up transformer; three-phase, 60 Hz, ONAN/ONAF/ONAF; Dual-voltage grounded-wye high side rated 240 or 120 kV with 13.8 kV delta low side; De-energized tap changer, copper windings, mineral oil, and suitable-for-step-up designation; Manufacture date is not completed on the reviewed drawing; 2012 is the drawing-approval date, not a claimed build yearThree units offered for allocation; availability and 4–8 week shipping schedule confirmed by J&J on October 1, 2026.; Nameplate rating: 240/320/400 MVA with ONAN/ONAF/ONAF cooling. Maximum stated duty: 400 MVA step-up or 250 MVA step-down.; Three-phase, 60 Hz; 525 kV grounded-wye high side, 69 kV wye low side, and 13.7 kV buried-delta tertiary rated 90 MVA.; Copper windings; MR on-load tap changer; HV tap range 472.5–577.5 kV (±10%).; HV BIL: 1550 kV winding / 1675 kV bushing. LV BIL: 350 kV.; Nameplate H-X impedance: 12.90% at 240 MVA base, 525/69 kV, 85°C.; Supplied 2022 factory acceptance test report records Passed for the documented unit. Nameplate, outline drawing and test report available through J&J; match the records to all three units before purchase.
Evidence reviewedSerial-specific approval nameplate drawing reviewedSupplied nameplate, outline drawing and factory acceptance test report
Technical value basisSupplied approval nameplate drawing; its approval date is not a manufacture date.Supplied nameplate for one documented unit; match the complete package to each of the three offered units.
Details to confirmFinal manufacture year, tested impedance/base and selected voltage/tap connection; Current preservation, final oil quantity, dimensions, shipping weight and accessory scopeMatching records for each offered unit, current condition, included accessories and transport scope; Unit-specific factory tests, present preservation and the step-down duty limit
Represented conditionBrand new, never used and never energized2022 manufacture shown in supplied nameplate; condition and service history confirmed with quotation
Equipment locationUSAInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; approval nameplate drawing reviewed; subject to prior sale and written reconfirmationImmediately available; estimated 4–8 weeks to ship; subject to prior sale
Availability last confirmed2026-09-242026-10-01
Shipping estimateRequest a written dispatch and delivery schedule4–8 weeks to ship
Nameplate reviewedYes — request the unit packageYes — request the unit package
Drawings reviewedYes — request matching unit drawingsYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist