Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare3 Rebuilt ABB 59.7 MVA-Class 230/13.8 kV TransformersJJ-ABB-230-13-3New 220 MVA 230/34.5 kV ABB/Hitachi TransformerJJ-230-220-1
ManufacturerABBABB / Hitachi
Rating / output40/53.3 MVA at 55 C; 44.8/59.7 MVA at 65 C132/176/220 MVA
Voltage / winding arrangement230 kV delta / 13.8 kV grounded wye230/34.5 kV with 13.8 kV buried-delta tertiary
Vector groupDelta–Grounded Wye; clock to confirmYNyn0d1 — Wye–Wye / Delta
Frequency60 Hz60 Hz
CoolingOA / FA / FAONAN / ONAF / ODAF
Impedance and base9.99% represented; MVA base not establishedH–X: 10.47% at 132 MVA, 230/34.5 kV
Tap changerFive-position HV DETC represented at 241.5, 235.75, 230, 224.25 and 218.5 kVHV OLTC; nameplate tap table spans 205.8–254.2 kV; confirm the selected tap and final switch schedule
Insulation / BILNot documented; confirm with J&JHV line 900 kV; HV neutral, LV and tertiary 200 kV
Quantity represented3 represented units1 unit
Technical details / open items1989 manufacture represented; three-phase, 60 Hz, copper windings; OA/FA/FA cooling, 55/65 C rise, and 9.99% represented impedance; HV taps represented at 241.5, 235.75, 230, 224.25, and 218.5 kV; Supplied equipment photo shown; request matching records, rebuild scope, tests and included accessories for all three units through J&J132/176/220 MVA, 230 kV grounded-wye high side and 34.5 kV grounded-wye low side; YNyn0d1 connection documented in the manufacturer factory test report; 13.8 kV buried-delta tertiary; 2021 ABB rating-plate drawing; three-phase, 60 Hz, ONAN/ONAF/ODAF cooling; Contact Tommy Marco directly for the technical package, price, and delivery arrangements; Nameplate impedance: 10.47% on a 132 MVA, 230/34.5 kV base; final configuration confirmed with the technical package
Evidence reviewedSeller specification sheet and equipment photo reviewedManufacturer nameplate and factory test report reviewed
Technical value basisSeller specification and equipment photograph; confirm all three individual nameplates and rebuild records.Supplied unit nameplate and historical factory photograph; current inspection and matching factory records remain necessary.
Details to confirmAll three matching nameplates, impedance bases, BIL and detailed rebuild scopes; Current inspection, tests, accessory completeness and individual transport dimensions/weightsCurrent preservation, complete factory-test reports and included accessory schedule; Overall/shipping dimensions, shipping weight, oil quantity and loading arrangements
Represented conditionRebuilt; three ABB 230/13.8 kV transformers. Rebuild scope and included accessories are confirmed with the quotationBrand new, never used and never energized
Equipment locationUSAUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; specification sheet reviewed; subject to prior sale and written reconfirmationAvailable; confirmed by J&J on September 24, 2026; subject to prior sale and written confirmation
Availability last confirmed2026-09-242026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist