CompareNew 220 MVA 230/34.5 kV ABB/Hitachi TransformerJJ-230-220-1ILJIN 167 MVA 230/34.5 kV New / Unused TransformerJJ-ILJIN-230-167
ManufacturerABB / HitachiILJIN Electric
Rating / output132/176/220 MVA100/133/167 MVA
Voltage / winding arrangement230/34.5 kV with 13.8 kV buried-delta tertiary230/34.5 kV; tertiary voltage to confirm
Vector groupYNyn0d1 — Wye–Wye / DeltaYNyn0+d represented; tertiary clock to confirm
Frequency60 HzNot documented; confirm with J&J
CoolingONAN / ONAF / ODAFNot documented; confirm with J&J
Impedance and baseH–X: 10.47% at 132 MVA, 230/34.5 kVNot documented; confirm with J&J
Tap changerHV OLTC; nameplate tap table spans 205.8–254.2 kV; confirm the selected tap and final switch scheduleNot documented; confirm with J&J
Insulation / BILHV line 900 kV; HV neutral, LV and tertiary 200 kVNot documented; confirm with J&J
Quantity represented1 unit1 represented unit
Technical details / open items132/176/220 MVA, 230 kV grounded-wye high side and 34.5 kV grounded-wye low side; YNyn0d1 connection documented in the manufacturer factory test report; 13.8 kV buried-delta tertiary; 2021 ABB rating-plate drawing; three-phase, 60 Hz, ONAN/ONAF/ODAF cooling; Contact Tommy Marco directly for the technical package, price, and delivery arrangements; Nameplate impedance: 10.47% on a 132 MVA, 230/34.5 kV base; final configuration confirmed with the technical packageThe individual August offer expressly identifies this ILJIN option as new/unused and never energized; that offer was forwarded again September 30, 2026.; A separate September 30 equipment table repeats 100/133/167 MVA and 230/34.5 kV. Dispatch location and allocation require current confirmation through J&J.; The supplied vector description is YNyn0+d. Obtain the individual nameplate, tertiary rating and voltage, vector clock, frequency, cooling stages and test records before duty approval.; Confirm preservation and storage history, actual warranty provider and transferable written coverage, loading and shipping terms with the quotation.; This ILJIN offer is distinct from the separately listed Fortune Electric 167 MVA transformer; no additional Fortune unit is implied.
Evidence reviewedManufacturer nameplate and factory test report reviewedIndividual written offer, repeated in a September 30 equipment listing
Technical value basisSupplied unit nameplate and historical factory photograph; current inspection and matching factory records remain necessary.Received written equipment offer; individual technical records require review.
Details to confirmCurrent preservation, complete factory-test reports and included accessory schedule; Overall/shipping dimensions, shipping weight, oil quantity and loading arrangementsIndividual nameplate, frequency, cooling/rise, tertiary duty and vector clock; Impedance/base, BIL, taps, copper/fluid specification, factory tests, preservation and transport scope
Represented conditionBrand new, never used and never energizedNew / unused and never energized, as explicitly represented in the offer
Equipment locationUSAInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; confirmed by J&J on September 24, 2026; subject to prior sale and written confirmationListed in received September 30, 2026 offers; current allocation, condition and dispatch timing require written confirmation
Availability last confirmed2026-09-24Request current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageNot recorded as reviewed; request it
Drawings reviewedYes — request matching unit drawingsNot recorded as reviewed; request them
Factory test report reviewedReport reviewed; confirm matching records for each unitNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.