Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
CompareABB 133 MVA 115/13.2 kV Pre-Owned GSUJJ-TX-208Westinghouse 22.4 MVA 115/24.9 kV Used TransformersJJ-WEST-115-22-2
ManufacturerABB Power T&DWestinghouse
Rating / output80/106.67/133.33 MVA at 55C rise; 89.6/119.47/149.33 MVA at 65C rise12/16/20/22.4 MVA; rating-stage basis to confirm
Voltage / winding arrangement115 kV grounded wye / 13.2 kV delta115/24.9 kV
Vector groupGrounded wye / delta; clock to confirmWinding connections to confirm
Frequency60 HzNot documented; confirm with J&J
CoolingOA / FA / FANot documented; confirm with J&J
Impedance and base6.0% at 80 MVANot documented; confirm with J&J
Tap changerFive-position de-energized HV tap changer, ±2 × 2.5% (±5%); 120.75 to 109.25 kVNot documented; confirm with J&J
Insulation / BILHV winding and bushing 550 kV; LV winding/bushing and HV neutral 110 kVNot documented; confirm with J&J
Quantity representedOne offered unit; subject to prior sale and written allocation2 represented units
Technical details / open itemsOEM nameplate and supplied technical packet.; Design/nameplate basis: OA/FA/FA, 60 Hz, 55C / 65C dual ratings; Grounded wye / delta.; Tap changer: Five-position de-energized tap changer, +/-2 x 2.5% (+/-5%).; Impedance: 6.0% at 80 MVA; BIL: HV 550 kV; LV and HV neutral 110 kV.; Supplied June 2026 oil-analysis summary and OEM drawings/nameplate; inspection and complete reports available through J&J for qualified review.; Request current service history, inspection and full laboratory reports.; Two supplied equipment photographs are shown. Current condition and complete accessory scope require inspection; request the current matching photo set through J&J.; Ask J&J for current price, warranty, inspection and delivery terms.The written offer identifies two Westinghouse units with the stated 115/24.9 kV ratio and four MVA ratings.; Pre-owned/reconditioned condition and new bushings are offer representations. Obtain the work scope and present inspection findings before purchase.; Request a readable nameplate for each unit, the rating-stage and temperature-rise basis, winding connections, frequency, taps, impedance and current tests.; Confirm accessories, any included breakers, loading, transport and release timing with the quotation. The review date is not a fresh availability check.
Evidence reviewedOEM nameplate and supplied technical packetReceived written equipment offer; individual nameplates require review
Technical value basisSupplied OEM nameplate and drawings; historical oil-analysis summary is separate from current condition.Received written offer; individual nameplates have not been reviewed.
Details to confirmCurrent inspection, complete oil laboratory reports, service history and accessory operation/completeness; Vector clock, final dismantling/loading schedule and current transport dimensions/weightsBoth individual nameplates, frequency, connections, cooling, rise, impedance/base, BIL and taps; Current condition, tests, detailed reconditioning scope, dimensions/weights and accessories
Represented conditionPre-owned installed surplus; detailed service history requires confirmationPre-owned / reconditioned; new bushings represented in the offer
Equipment locationLocation confirmed with quotationLocation confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityOffered for inspection and purchase; current release, disassembly and loading dates require written confirmationOffered September 20, 2026; current availability and allocation require written confirmation
Availability last confirmedRequest current confirmationRequest current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageNot recorded as reviewed; request it
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist