Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
CompareABB 133 MVA 115/13.2 kV Pre-Owned GSUJJ-TX-20860 MVA 115/34.5 kV Virginia TransformersJJ-TX-006
ManufacturerABB Power T&DVirginia Transformer Corp.
Rating / output80/106.67/133.33 MVA at 55C rise; 89.6/119.47/149.33 MVA at 65C rise36/48/60 MVA
Voltage / winding arrangement115 kV grounded wye / 13.2 kV delta115 kV delta / 34.5 kV grounded wye
Vector groupGrounded wye / delta; clock to confirmDyn1
Frequency60 Hz60 Hz
CoolingOA / FA / FAONAN / ONAF / ONAF
Impedance and base6.0% at 80 MVA8.42%, 8.41% and 8.46% at 36 MVA, by unit
Tap changerFive-position de-energized HV tap changer, ±2 × 2.5% (±5%); 120.75 to 109.25 kVABB HV LTC; 103.5–126.5 kV (±10%); 16 raise / 16 lower steps of 0.625%
Insulation / BILHV winding and bushing 550 kV; LV winding/bushing and HV neutral 110 kVHV line 550 kV; LV 200 kV
Quantity representedOne offered unit; subject to prior sale and written allocation3 units
Technical details / open itemsOEM nameplate and supplied technical packet.; Design/nameplate basis: OA/FA/FA, 60 Hz, 55C / 65C dual ratings; Grounded wye / delta.; Tap changer: Five-position de-energized tap changer, +/-2 x 2.5% (+/-5%).; Impedance: 6.0% at 80 MVA; BIL: HV 550 kV; LV and HV neutral 110 kV.; Supplied June 2026 oil-analysis summary and OEM drawings/nameplate; inspection and complete reports available through J&J for qualified review.; Request current service history, inspection and full laboratory reports.; Two supplied equipment photographs are shown. Current condition and complete accessory scope require inspection; request the current matching photo set through J&J.; Ask J&J for current price, warranty, inspection and delivery terms.ONAN/ONAF/ONAF, 60 Hz, three-phase, vector group Dyn1; Measured impedance: 8.42%, 8.41%, and 8.46% at 36 MVA by unit; Copper windings, Type II mineral oil, and ABB HV LTC
Evidence reviewedOEM nameplate and supplied technical packetThree unit-specific nameplates reviewed
Technical value basisSupplied OEM nameplate and drawings; historical oil-analysis summary is separate from current condition.Three individual nameplates reviewed; the impedance values vary by unit.
Details to confirmCurrent inspection, complete oil laboratory reports, service history and accessory operation/completeness; Vector clock, final dismantling/loading schedule and current transport dimensions/weightsMatch each unit to its factory tests and approved accessory schedule; Current preservation, overall/shipping dimensions and individual shipping weights
Represented conditionPre-owned installed surplus; detailed service history requires confirmationBrand new, never used and never energized; February-March 2026 nameplates reviewed
Equipment locationLocation confirmed with quotationUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityOffered for inspection and purchase; current release, disassembly and loading dates require written confirmationAvailable; three unit-specific nameplates reviewed; subject to prior sale and written reconfirmation
Availability last confirmedRequest current confirmation2026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales