Transformer opportunity · JJ-TX-006

Virginia Transformer 36/48/60 MVA 115/34.5 kV Transformers

Equipment location: USA. J&J is based in Sugar Land, Texas and serves projects nationwide.

Condition: Brand new, never used and never energized; February-March 2026 nameplates reviewed. Contact J&J about this Virginia Transformer Corp. unit with 36/48/60 MVA, 115 kV delta / 34.5 kV grounded wye, 60 Hz, and OLTC. Three unit-specific nameplates reviewed. Availability is subject to prior sale and written confirmation. Contact Tommy Marco at 346-276-9540 or tommy@jjtransformers.com with MVA, voltages, quantity, site, and need-by date. Listing information reviewed .

Availability confirmedConfirmed by J&J Request current allocation and release terms · subject to prior sale
Request equipment photos

Public photos are not shown for this listing. Ask J&J for a current photo set and the matching technical records.

Request photos through J&J

Equipment summary

Specifications and scope

Unit IDJJ-TX-006
ManufacturerVirginia Transformer Corp.
Manufacturer basisThree unit-specific nameplates reviewed
Rating36/48/60 MVA
Voltage / output115 kV delta / 34.5 kV grounded wye
Frequency60 Hz
Vector groupDyn1
TertiaryNot documented; confirm the complete winding arrangement
Quantity3 units
AvailabilityAvailable; three unit-specific nameplates reviewed; subject to prior sale and written reconfirmation
Project historyFactory-built for a project that did not proceed to energization
Energization historyNever energized
Condition basisBrand new, never used and never energized; February-March 2026 nameplates reviewed
Condition confirmed by J&J
Current locationUSA
Listing information reviewed

Technical values and record basis

Three individual nameplates reviewed; the impedance values vary by unit.

PhasesThree-phase
CoolingONAN / ONAF / ONAF
Temperature rise65°C
Conductor / fluidCopper / Type II mineral oil
Tap changerABB HV LTC; 103.5–126.5 kV (±10%); 16 raise / 16 lower steps of 0.625%
Impedance and base8.42%, 8.41% and 8.46% at 36 MVA, by unit
Insulation / BILHV line 550 kV; LV 200 kV
Winding connectionsDelta / grounded wye, Dyn1

Details to confirm for this listing

  • Match each unit to its factory tests and approved accessory schedule
  • Current preservation, overall/shipping dimensions and individual shipping weights

Technical highlights

  • ONAN/ONAF/ONAF, 60 Hz, three-phase, vector group Dyn1
  • Measured impedance: 8.42%, 8.41%, and 8.46% at 36 MVA by unit
  • Copper windings, Type II mineral oil, and ABB HV LTC

Evidence reviewed

Three unit-specific nameplates reviewed

Records apply only to the stated unit or design basis.

Availability and terms

Available; three unit-specific nameplates reviewed; subject to prior sale and written reconfirmation

Ask for the current technical package, price, included accessories and delivery terms.

Confirm the purchase and delivery scope

Ask J&J to confirm the proposed unit’s allocation, price, inspection access, included accessories, loading and freight boundary, receiving arrangements, release schedule, deposit or reservation terms and any applicable warranty. Photos, matching records and inspection arrangements are coordinated through J&J.

Request written terms

Check this transformer against your project

Compare the complete winding arrangement and condition evidence before requesting a quote. A matching voltage ratio alone does not establish suitability.

For this listing’s photographs, reports, pricing and current status, call 346-276-9540 or email Tommy with unit ID JJ-TX-006.