Compare120 MVA 138/34.5 kV Georgia Solar GSUJJ-TX-004Five 110 MVA 138/34.5 kV Kolektor ETRA GSUsJJ-138-110-5
ManufacturerGeorgia TransformerKolektor ETRA
Rating / output72/96/120 MVA; 25.2/33.6/42 MVA tertiary66/88/110 MVA; 22/29.333/36.666 MVA tertiary
Voltage / winding arrangement138/34.5 kV with 12 kV buried-delta tertiary138/34.5 kV with 13.8 kV tertiary
Vector groupYNyn0+d1YNyn0+d11
Frequency60 Hz60 Hz
CoolingONAN / ONAF1 / ONAF2ONAN / ONAF1 / ONAF2
Impedance and baseMeasured H–X: 6.93% at 72 MVA; design value 7.2%Reviewed nameplate H–X: 8.09% at 66 MVA; supplied FAT reports 13.41% at 110 MVA. Match the test and plate to the selected unit.
Tap changerHV OLTC; 117.3–158.7 kV (±15%); confirm the final switch and step scheduleHV OLTC; 124.2–151.8 kV (±10%); 16 raise / 16 lower steps of 0.625% on the reviewed plate
Insulation / BILHV line 650 kV; HV neutral, LV line and LV neutral 200 kVNot documented; confirm with J&J
Quantity represented1 documented unit5 units; matching unit packages available on request
Technical details / open itemsSolar GSU design; ONAN/ONAF1/ONAF2, 60 Hz, three-phase; Vector group YNyn0+d1 with HV OLTC and conservator oil system; Nameplate rating is used; an outline-drawing discrepancy requires final seller confirmationGSU duty; ONAN/ONAF1/ONAF2, 60 Hz, three-phase, vector group YNyn0+d11; Measured impedance: 13.41% on a 110 MVA base at nominal tap; 2020 factory tests passed; those records do not establish current condition; Five-unit lot includes two 2020 builds and three 2021 builds; request all five serial-specific packages before quotation
Evidence reviewedSerial-specific nameplate and approval drawings reviewedFive-unit opportunity confirmed by seller; rating plate and FAT package reviewed for one unit
Technical value basisSupplied unit nameplate; the nameplate takes precedence over the differing outline-drawing rating.One supplied nameplate and one factory-test package; values are not established for all five units.
Details to confirmResolve the outline-drawing rating discrepancy and confirm the final drawing revision; Current preservation, complete tests, dimensions and included accessory scheduleAll five matching nameplates, insulation levels, approved drawings and factory tests; Reconcile unit-specific impedance bases; confirm current preservation and individual shipping weights
Represented conditionBrand new, never used and never energized; approval drawings reviewedBrand new, never used and never energized; 2020 factory records reviewed for one unit
Equipment locationUSAInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; engineering package reviewed; subject to prior sale and written reconfirmationAvailable; 5 units represented; remaining unit packages require review; subject to prior sale and written confirmation
Availability last confirmed2026-09-242026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageYes — request the unit package
Drawings reviewedYes — request matching unit drawingsNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist