Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare60 MVA 115/34.5 kV Virginia TransformersJJ-TX-006155 MVA 115/34.5 kV Virginia TransformerJJ-TX-107
ManufacturerVirginia Transformer Corp.Virginia Transformer
Rating / output36/48/60 MVA93/124/155 MVA
Voltage / winding arrangement115 kV delta / 34.5 kV grounded wye115/34.5 kV
Vector groupDyn1Winding connections and phase shift to confirm
Frequency60 HzNot documented; confirm with J&J
CoolingONAN / ONAF / ONAFNot documented; confirm with J&J
Impedance and base8.42%, 8.41% and 8.46% at 36 MVA, by unitNot documented; confirm with J&J
Tap changerABB HV LTC; 103.5–126.5 kV (±10%); 16 raise / 16 lower steps of 0.625%Not documented; confirm with J&J
Insulation / BILHV line 550 kV; LV 200 kVNot documented; confirm with J&J
Quantity represented3 units1 schedule entry; individual identity to confirm
Technical details / open itemsONAN/ONAF/ONAF, 60 Hz, three-phase, vector group Dyn1; Measured impedance: 8.42%, 8.41%, and 8.46% at 36 MVA by unit; Copper windings, Type II mineral oil, and ABB HV LTCRatings and manufacturer are transcribed from the J&J-submitted schedule; verify them against the matching nameplate and current technical package.; Service history, present condition, frequency, winding arrangement, impedance, tap changer and accessories require unit-specific confirmation.; Historical schedule dates do not establish current dispatch timing, manufacture year or transferable warranty. Request present release terms and any applicable warranty in writing.
Evidence reviewedThree unit-specific nameplates reviewedJ&J-submitted inventory schedule; matching unit-specific technical records to confirm
Technical value basisThree individual nameplates reviewed; the impedance values vary by unit.Submitted inventory schedule; manufacturer and electrical rating are representations, not an individual nameplate match.
Details to confirmMatch each unit to its factory tests and approved accessory schedule; Current preservation, overall/shipping dimensions and individual shipping weightsIndividual identity and quantity, current photos, condition/service history and preservation; Frequency, cooling/rise, winding connections and clock, impedance/base, BIL, conductor/fluid and tap schedule; Factory/current tests, included accessories, dimensions/weights and final release/transport scope
Represented conditionBrand new, never used and never energized; February-March 2026 nameplates reviewedCondition and service history require confirmation
Equipment locationUSALocation confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; three unit-specific nameplates reviewed; subject to prior sale and written reconfirmationListed for inquiry by J&J; current allocation and release timing require written confirmation
Availability last confirmed2026-09-24Request current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageNot recorded as reviewed; request it
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist