Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
CompareWestinghouse 22.4 MVA 115/24.9 kV Used TransformersJJ-WEST-115-22-2208 MVA 115/34.5 kV Transformer — 2027JJ-TX-202
ManufacturerWestinghouseManufacturer disclosed in the qualified technical package
Rating / output12/16/20/22.4 MVA; rating-stage basis to confirm124.8/166.4/208 MVA
Voltage / winding arrangement115/24.9 kV115 kV HV / 34.5 kV LV
Vector groupWinding connections to confirmGrounded wye / grounded wye
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JH–X 9% at 125 MVA (supplied design sheet)
Tap changerNot documented; confirm with J&JHV OLTC ±8 × 1.25% (±10%); no taps shown on X or Y windings
Insulation / BILNot documented; confirm with J&JHV line 550 kV; HV neutral, LV line and LV neutral 200 kV
Quantity represented2 represented units1 offered position
Technical details / open itemsThe written offer identifies two Westinghouse units with the stated 115/24.9 kV ratio and four MVA ratings.; Pre-owned/reconditioned condition and new bushings are offer representations. Obtain the work scope and present inspection findings before purchase.; Request a readable nameplate for each unit, the rating-stage and temperature-rise basis, winding connections, frequency, taps, impedance and current tests.; Confirm accessories, any included breakers, loading, transport and release timing with the quotation. The review date is not a fresh availability check.Supplied design data sheet; final unit-specific nameplate and FAT pending.; Ask J&J for the included U.S.-port shipping, commissioning and manufacturer warranty scope in the written offer.; Modifications can be reviewed before completion; feasibility, cost and schedule impact require OEM confirmation.; Any warranty provider, scope, transfer eligibility, start date and commissioning boundary must appear in the written quotation.; Design basis: ONAN/ONAF1/ONAF2, 60 Hz, 65 C temperature rise; grounded-wye high and low sides.; HV OLTC design range ±10%; preliminary 13.8 kV open-delta tertiary. Final unit-specific configuration requires approval.; Design H-X impedance: 9% at a 125 MVA base. This is a design-sheet value, not a final tested result.
Evidence reviewedReceived written equipment offer; individual nameplates require reviewSupplied design data sheet; final unit-specific nameplate and FAT pending
Technical value basisReceived written offer; individual nameplates have not been reviewed.Supplied guaranteed design sheet; these are design values, not final tested values for an individually matched unit.
Details to confirmBoth individual nameplates, frequency, connections, cooling, rise, impedance/base, BIL and taps; Current condition, tests, detailed reconditioning scope, dimensions/weights and accessoriesFinal unit-specific nameplate, approved revision, tested impedance/losses and final tertiary arrangement; Conductor, OLTC switch specification, complete accessories, current photos and preservation or manufacturing progress
Represented conditionPre-owned / reconditioned; new bushings represented in the offerFactory manufacturing position; completion pending
Equipment locationLocation confirmed with quotationDispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityOffered September 20, 2026; current availability and allocation require written confirmation2027 manufacturing positions offered for allocation; current release terms require written confirmation
Availability last confirmedRequest current confirmationRequest current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleProjected 2027 completion; shipment and receiving dates require written confirmation
Nameplate reviewedNot recorded as reviewed; request itNot recorded as reviewed; request it
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist