Your equipment shortlist
Compare equipment before you request it.
Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.
| Compare | Westinghouse 22.4 MVA 115/24.9 kV Used TransformersJJ-WEST-115-22-2 | 110 MVA 115/34.5 kV ABB TransformerJJ-TX-103 |
|---|---|---|
| Manufacturer | Westinghouse | ABB |
| Rating / output | 12/16/20/22.4 MVA; rating-stage basis to confirm | 66/88/110 MVA |
| Voltage / winding arrangement | 115/24.9 kV | 115/34.5 kV |
| Vector group | Winding connections to confirm | Winding connections and phase shift to confirm |
| Frequency | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Cooling | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 2 represented units | 1 schedule entry; individual identity to confirm |
| Technical details / open items | The written offer identifies two Westinghouse units with the stated 115/24.9 kV ratio and four MVA ratings.; Pre-owned/reconditioned condition and new bushings are offer representations. Obtain the work scope and present inspection findings before purchase.; Request a readable nameplate for each unit, the rating-stage and temperature-rise basis, winding connections, frequency, taps, impedance and current tests.; Confirm accessories, any included breakers, loading, transport and release timing with the quotation. The review date is not a fresh availability check. | Ratings and manufacturer are transcribed from the J&J-submitted schedule; verify them against the matching nameplate and current technical package.; Service history, present condition, frequency, winding arrangement, impedance, tap changer and accessories require unit-specific confirmation.; Historical schedule dates do not establish current dispatch timing, manufacture year or transferable warranty. Request present release terms and any applicable warranty in writing. |
| Evidence reviewed | Received written equipment offer; individual nameplates require review | J&J-submitted inventory schedule; matching unit-specific technical records to confirm |
| Technical value basis | Received written offer; individual nameplates have not been reviewed. | Submitted inventory schedule; manufacturer and electrical rating are representations, not an individual nameplate match. |
| Details to confirm | Both individual nameplates, frequency, connections, cooling, rise, impedance/base, BIL and taps; Current condition, tests, detailed reconditioning scope, dimensions/weights and accessories | Individual identity and quantity, current photos, condition/service history and preservation; Frequency, cooling/rise, winding connections and clock, impedance/base, BIL, conductor/fluid and tap schedule; Factory/current tests, included accessories, dimensions/weights and final release/transport scope |
| Represented condition | Pre-owned / reconditioned; new bushings represented in the offer | Condition and service history require confirmation |
| Equipment location | Location confirmed with quotation | Location confirmed with quotation |
| Technical records reviewed | 2026-10-08 | 2026-10-08 |
| Availability | Offered September 20, 2026; current availability and allocation require written confirmation | Listed for inquiry by J&J; current allocation and release timing require written confirmation |
| Availability last confirmed | Request current confirmation | Request current confirmation |
| Shipping estimate | Request a written dispatch and delivery schedule | Request a written dispatch and delivery schedule |
| Nameplate reviewed | Not recorded as reviewed; request it | Not recorded as reviewed; request it |
| Drawings reviewed | Not recorded as reviewed; request them | Not recorded as reviewed; request them |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Request more info | Request more info |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist