Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare65 MVA 138/13.8 kV Reconditioned GSUJJ-TX-20950 MVA-Class 138/13.8 kV Substation PackageJJ-TX-007
ManufacturerABBManufacturer to confirm
Rating / output39/52/65 MVA at 65°C rise30/39.9/50 MVA at 55 C; 33.6/44.7/56 MVA at 65 C
Voltage / winding arrangement138 kV grounded wye / 13.8 kV delta138 kV delta / 13.8 kV grounded wye
Vector groupGrounded wye / delta; clock to confirmDelta–Grounded Wye; clock to confirm
Frequency60 Hz60 Hz
CoolingONAN / ONAF / ONAF; legacy OA / FA / FA in cutsheetsONAN / ONAF / ONAF
Impedance and base9.51% at 39 MVA shown on replacement nameplate; not a new field impedance testNot documented; confirm with J&J
Tap changerFive-position de-energized HV tap changer: 144.9, 141.45, 138, 134.55, 131.1 kV (±2 × 2.5%, ±5%)Five-position HV DETC: 131.1, 134.55, 138, 141.45 and 144.9 kV (±5%, 2.5% steps)
Insulation / BILHV winding 550 kV / bushing 650 kV; LV winding 110 kV / bushings 150 kV; HV neutral bushing 150 kVHV 650 kV; LV 110 kV, drawing basis
Quantity representedOne unit; current allocation subject to written confirmation1 represented design package
Technical details / open itemsABB is identified by the supplied replacement nameplate and historical refurbishment/testing report; confirm the original OEM plate and provenance.; Design/nameplate basis: ONAN/ONAF/ONAF, 60 Hz, 65C; Grounded wye / delta.; Tap changer: Five-position de-energized HV tap changer (144.9, 141.45, 138, 134.55, 131.1 kV; +/-2 x 2.5%).; Impedance: 9.51% at 39 MVA as shown in the supplied nameplate drawing; final test values to compare; BIL: HV winding 550 kV; LV winding 110 kV.; 2022 refurbishment and electrical-test report plus supplied nameplate drawing; no pre-refurbishment test records represented.; The supplied nameplate drawing states 138/13.8 kV; a voltage field in the 2022 test report states 115/13.8 kV. Obtain reconciliation and a matching current test package before technical acceptance.; Exterior photographs shown are from the 2022 refurbishment report. Request current dated photographs and inspect present condition through J&J.; Seller reports minimal previous service. J&J confirms it has not been installed since the 2022 refurbishment and has been maintained in storage. Earlier operating records are unavailable.; Documented exterior and cabinet cleaning/painting, bushings and LV bus bars, spare gaskets and bushing hardware; electrical testing included turns ratio, winding resistance, insulation resistance, power factor, excitation current and SFRA.; Inspection can be arranged with a 10% deposit, refundable only if the unit fails the buyer's tests or does not match the advertised specifications and condition. Confirm exact terms in the written offer.Oil-immersed substation transformer; ONAN/ONAF/ONAF, 60 Hz, three-phase; HV de-energized tap range: 131.1-144.9 kV; Final impedance, serial number, test data, and manufacture date are not populated
Evidence reviewedABB identified by the supplied replacement nameplate and historical refurbishment/test report; original OEM provenance to confirmProject-specific supplied approval drawings reviewed; final equipment OEM and serial identity require confirmation
Technical value basisSupplied 2022 replacement nameplate and historical refurbishment/test report; current inspection is still required.Supplied approval design drawings; a completed individual nameplate and final equipment identity have not been established.
Details to confirmConfirm the original OEM plate and vector clock; reconcile inconsistent voltage text in the historical test templates; Current inspection and oil analysis, complete earlier service history, accessories and final handling/shipping dimensionsFinal OEM, individual equipment identity, manufacture year, tested impedance and factory reports; Final drawings, current preservation, complete accessories and shipping configuration
Represented conditionReconditioned used transformer; refurbishment completed in 2022Brand new, never used and never energized; 2024 approval drawings reviewed; serial identity requires confirmation
Equipment locationLocation confirmed with quotationUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityOffered by J&J; seller indicated 6-8 weeks for preparation/delivery on October 1, 2026. Current inspection, loading and delivery schedule by written confirmation.Available; approval drawings reviewed; unit identity requires documentation; subject to prior sale and written confirmation
Availability last confirmedRequest current confirmation2026-09-24
Shipping estimate6–8 weeks quoted October 1, 2026; current preparation, loading and delivery schedule to confirmRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageNot recorded as reviewed; request it
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist