Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
CompareABB 133 MVA 115/13.2 kV Pre-Owned GSUJJ-TX-20895 MVA 115/34.5 kV Virginia TransformerJJ-TX-101
ManufacturerABB Power T&DVirginia Transformer
Rating / output80/106.67/133.33 MVA at 55C rise; 89.6/119.47/149.33 MVA at 65C rise57/76/95 MVA
Voltage / winding arrangement115 kV grounded wye / 13.2 kV delta115/34.5 kV
Vector groupGrounded wye / delta; clock to confirmWinding connections and phase shift to confirm
Frequency60 HzNot documented; confirm with J&J
CoolingOA / FA / FANot documented; confirm with J&J
Impedance and base6.0% at 80 MVANot documented; confirm with J&J
Tap changerFive-position de-energized HV tap changer, ±2 × 2.5% (±5%); 120.75 to 109.25 kVNot documented; confirm with J&J
Insulation / BILHV winding and bushing 550 kV; LV winding/bushing and HV neutral 110 kVNot documented; confirm with J&J
Quantity representedOne offered unit; subject to prior sale and written allocation2 schedule entries; distinct unit identities to confirm
Technical details / open itemsOEM nameplate and supplied technical packet.; Design/nameplate basis: OA/FA/FA, 60 Hz, 55C / 65C dual ratings; Grounded wye / delta.; Tap changer: Five-position de-energized tap changer, +/-2 x 2.5% (+/-5%).; Impedance: 6.0% at 80 MVA; BIL: HV 550 kV; LV and HV neutral 110 kV.; Supplied June 2026 oil-analysis summary and OEM drawings/nameplate; inspection and complete reports available through J&J for qualified review.; Request current service history, inspection and full laboratory reports.; Two supplied equipment photographs are shown. Current condition and complete accessory scope require inspection; request the current matching photo set through J&J.; Ask J&J for current price, warranty, inspection and delivery terms.Ratings and manufacturer are transcribed from the J&J-submitted schedule; verify them against the matching nameplate and current technical package.; Service history, present condition, frequency, winding arrangement, impedance, tap changer and accessories require unit-specific confirmation.; Historical schedule dates do not establish current dispatch timing, manufacture year or transferable warranty. Request present release terms and any applicable warranty in writing.; Repeated schedule entries are grouped here; quantity is not represented as independently verified stock.
Evidence reviewedOEM nameplate and supplied technical packetJ&J-submitted inventory schedule; matching unit-specific technical records to confirm
Technical value basisSupplied OEM nameplate and drawings; historical oil-analysis summary is separate from current condition.Submitted inventory schedule; manufacturer and electrical rating are representations, not an individual nameplate match.
Details to confirmCurrent inspection, complete oil laboratory reports, service history and accessory operation/completeness; Vector clock, final dismantling/loading schedule and current transport dimensions/weightsIndividual identity and quantity, current photos, condition/service history and preservation; Frequency, cooling/rise, winding connections and clock, impedance/base, BIL, conductor/fluid and tap schedule; Factory/current tests, included accessories, dimensions/weights and final release/transport scope
Represented conditionPre-owned installed surplus; detailed service history requires confirmationCondition and service history require confirmation
Equipment locationLocation confirmed with quotationLocation confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityOffered for inspection and purchase; current release, disassembly and loading dates require written confirmationListed for inquiry by J&J; current allocation and release timing require written confirmation
Availability last confirmedRequest current confirmationRequest current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageNot recorded as reviewed; request it
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist