Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare116 MVA 138 kV Transformer Positions — 2027JJ-TX-205Five 110 MVA 138/34.5 kV Kolektor ETRA GSUsJJ-138-110-5
ManufacturerManufacturer disclosed in the qualified technical packageKolektor ETRA
Rating / output116 MVA stated maximum66/88/110 MVA; 22/29.333/36.666 MVA tertiary
Voltage / winding arrangement138 kV HV; secondary voltage requires confirmation138/34.5 kV with 13.8 kV tertiary
Vector groupRequires confirmationYNyn0+d11
FrequencyRequires confirmation60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JReviewed nameplate H–X: 8.09% at 66 MVA; supplied FAT reports 13.41% at 110 MVA. Match the test and plate to the selected unit.
Tap changerNot documented; confirm with J&JHV OLTC; 124.2–151.8 kV (±10%); 16 raise / 16 lower steps of 0.625% on the reviewed plate
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented2 offered positions5 units; matching unit packages available on request
Technical details / open itemsSeller offer summary; exact cooling stages require confirmation.; Ask J&J for the included U.S.-port shipping, commissioning and manufacturer warranty scope in the written offer.; Modifications can be reviewed before completion; feasibility, cost and schedule impact require OEM confirmation.; Any warranty provider, scope, transfer eligibility, start date and commissioning boundary must appear in the written quotation.GSU duty; ONAN/ONAF1/ONAF2, 60 Hz, three-phase, vector group YNyn0+d11; Measured impedance: 13.41% on a 110 MVA base at nominal tap; 2020 factory tests passed; those records do not establish current condition; Five-unit lot includes two 2020 builds and three 2021 builds; request all five serial-specific packages before quotation
Evidence reviewedSeller offer summary; exact cooling stages require confirmationFive-unit opportunity confirmed by seller; rating plate and FAT package reviewed for one unit
Technical value basisReceived production offer and existing reviewed design package; final individual nameplates and factory tests remain pending.One supplied nameplate and one factory-test package; values are not established for all five units.
Details to confirmMatch the final design/rating and drawing revision to each offered manufacturing position; Final frequency, cooling/rise, winding duty, impedance/base, BIL, taps, accessories and transport dimensions/weightsAll five matching nameplates, insulation levels, approved drawings and factory tests; Reconcile unit-specific impedance bases; confirm current preservation and individual shipping weights
Represented conditionFactory manufacturing position; completion pendingBrand new, never used and never energized; 2020 factory records reviewed for one unit
Equipment locationDispatch location confirmed with quotationInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
Availability2027 manufacturing positions offered for allocation; current release terms require written confirmationAvailable; 5 units represented; remaining unit packages require review; subject to prior sale and written confirmation
Availability last confirmedRequest current confirmation2026-09-24
Shipping estimateProjected 2027 completion; shipment and receiving dates require written confirmationRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist