Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare208 MVA 138/34.5 kV Stored Surplus TransformerJJ-TX-201120 MVA 138/34.5 kV Georgia Solar GSUJJ-TX-004
ManufacturerManufacturer disclosed in the qualified technical packageGeorgia Transformer
Rating / output125/166/208 MVA72/96/120 MVA; 25.2/33.6/42 MVA tertiary
Voltage / winding arrangement138 kV HV / 34.5 kV LV138/34.5 kV with 12 kV buried-delta tertiary
Vector groupGrounded wye / grounded wyeYNyn0+d1
Frequency60 Hz60 Hz
CoolingONAN / ONAF1 / ONAF2ONAN / ONAF1 / ONAF2
Impedance and baseH–X 9% at 125 MVA (supplied design sheet)Measured H–X: 6.93% at 72 MVA; design value 7.2%
Tap changerHV OLTC ±8 × 1.25% (±10%); no taps shown on X or Y windingsHV OLTC; 117.3–158.7 kV (±15%); confirm the final switch and step schedule
Insulation / BILHV line 650 kV; HV neutral, LV line and LV neutral 200 kVHV line 650 kV; HV neutral, LV line and LV neutral 200 kV
Quantity represented1 offered position1 documented unit
Technical details / open itemsSupplied design data sheet; final unit-specific nameplate and FAT pending.; Ask J&J for the included U.S.-port shipping, commissioning and manufacturer warranty scope in the written offer.; Technical suitability subject to buyer review; Any warranty provider, scope, transfer eligibility, start date and commissioning boundary must appear in the written quotation.; Design basis: ONAN/ONAF1/ONAF2, 60 Hz, 65 C temperature rise; grounded-wye high and low sides.; HV OLTC design range ±10%; preliminary 13.8 kV open-delta tertiary. Final unit-specific configuration requires approval.; Design H-X impedance: 9% at a 125 MVA base. This is a design-sheet value, not a final tested result.Solar GSU design; ONAN/ONAF1/ONAF2, 60 Hz, three-phase; Vector group YNyn0+d1 with HV OLTC and conservator oil system; Nameplate rating is used; an outline-drawing discrepancy requires final seller confirmation
Evidence reviewedSupplied design data sheet; final unit-specific nameplate and FAT pendingSerial-specific nameplate and approval drawings reviewed
Technical value basisSupplied guaranteed design sheet; these are design values, not final tested values for an individually matched unit.Supplied unit nameplate; the nameplate takes precedence over the differing outline-drawing rating.
Details to confirmFinal unit-specific nameplate, approved revision, tested impedance/losses and final tertiary arrangement; Conductor, OLTC switch specification, complete accessories, current photos and preservation or manufacturing progressResolve the outline-drawing rating discrepancy and confirm the final drawing revision; Current preservation, complete tests, dimensions and included accessory schedule
Represented conditionSurplus in storage; service history requires confirmationBrand new, never used and never energized; approval drawings reviewed
Equipment locationDispatch location confirmed with quotationUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityStored surplus offered for allocation; current release terms require written confirmationAvailable; engineering package reviewed; subject to prior sale and written reconfirmation
Availability last confirmedRequest current confirmation2026-09-24
Shipping estimateRelease, loading and shipping dates confirmed with quotationRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales