Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare42 MVA 138/34.5 kV Virginia TransformerJJ-TX-102Five 110 MVA 138/34.5 kV Kolektor ETRA GSUsJJ-138-110-5
ManufacturerVirginia TransformerKolektor ETRA
Rating / output25.2/33.6/42 MVA66/88/110 MVA; 22/29.333/36.666 MVA tertiary
Voltage / winding arrangement138/34.5 kV138/34.5 kV with 13.8 kV tertiary
Vector groupWinding connections and phase shift to confirmYNyn0+d11
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JReviewed nameplate H–X: 8.09% at 66 MVA; supplied FAT reports 13.41% at 110 MVA. Match the test and plate to the selected unit.
Tap changerNot documented; confirm with J&JHV OLTC; 124.2–151.8 kV (±10%); 16 raise / 16 lower steps of 0.625% on the reviewed plate
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented1 schedule entry; individual identity to confirm5 units; matching unit packages available on request
Technical details / open itemsRatings and manufacturer are transcribed from the J&J-submitted schedule; verify them against the matching nameplate and current technical package.; Service history, present condition, frequency, winding arrangement, impedance, tap changer and accessories require unit-specific confirmation.; Historical schedule dates do not establish current dispatch timing, manufacture year or transferable warranty. Request present release terms and any applicable warranty in writing.GSU duty; ONAN/ONAF1/ONAF2, 60 Hz, three-phase, vector group YNyn0+d11; Measured impedance: 13.41% on a 110 MVA base at nominal tap; 2020 factory tests passed; those records do not establish current condition; Five-unit lot includes two 2020 builds and three 2021 builds; request all five serial-specific packages before quotation
Evidence reviewedJ&J-submitted inventory schedule; matching unit-specific technical records to confirmFive-unit opportunity confirmed by seller; rating plate and FAT package reviewed for one unit
Technical value basisSubmitted inventory schedule; manufacturer and electrical rating are representations, not an individual nameplate match.One supplied nameplate and one factory-test package; values are not established for all five units.
Details to confirmIndividual identity and quantity, current photos, condition/service history and preservation; Frequency, cooling/rise, winding connections and clock, impedance/base, BIL, conductor/fluid and tap schedule; Factory/current tests, included accessories, dimensions/weights and final release/transport scopeAll five matching nameplates, insulation levels, approved drawings and factory tests; Reconcile unit-specific impedance bases; confirm current preservation and individual shipping weights
Represented conditionCondition and service history require confirmationBrand new, never used and never energized; 2020 factory records reviewed for one unit
Equipment locationLocation confirmed with quotationInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityListed for inquiry by J&J; current allocation and release timing require written confirmationAvailable; 5 units represented; remaining unit packages require review; subject to prior sale and written confirmation
Availability last confirmedRequest current confirmation2026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales