Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare50 MVA-Class 138/13.8 kV Substation PackageJJ-TX-00765 MVA 138/13.8 kV Reconditioned GSUJJ-TX-209
ManufacturerManufacturer to confirmABB
Rating / output30/39.9/50 MVA at 55 C; 33.6/44.7/56 MVA at 65 C39/52/65 MVA at 65°C rise
Voltage / winding arrangement138 kV delta / 13.8 kV grounded wye138 kV grounded wye / 13.8 kV delta
Vector groupDelta–Grounded Wye; clock to confirmGrounded wye / delta; clock to confirm
Frequency60 Hz60 Hz
CoolingONAN / ONAF / ONAFONAN / ONAF / ONAF; legacy OA / FA / FA in cutsheets
Impedance and baseNot documented; confirm with J&J9.51% at 39 MVA shown on replacement nameplate; not a new field impedance test
Tap changerFive-position HV DETC: 131.1, 134.55, 138, 141.45 and 144.9 kV (±5%, 2.5% steps)Five-position de-energized HV tap changer: 144.9, 141.45, 138, 134.55, 131.1 kV (±2 × 2.5%, ±5%)
Insulation / BILHV 650 kV; LV 110 kV, drawing basisHV winding 550 kV / bushing 650 kV; LV winding 110 kV / bushings 150 kV; HV neutral bushing 150 kV
Quantity represented1 represented design packageOne unit; current allocation subject to written confirmation
Technical details / open itemsOil-immersed substation transformer; ONAN/ONAF/ONAF, 60 Hz, three-phase; HV de-energized tap range: 131.1-144.9 kV; Final impedance, serial number, test data, and manufacture date are not populatedABB is identified by the supplied replacement nameplate and historical refurbishment/testing report; confirm the original OEM plate and provenance.; Design/nameplate basis: ONAN/ONAF/ONAF, 60 Hz, 65C; Grounded wye / delta.; Tap changer: Five-position de-energized HV tap changer (144.9, 141.45, 138, 134.55, 131.1 kV; +/-2 x 2.5%).; Impedance: 9.51% at 39 MVA as shown in the supplied nameplate drawing; final test values to compare; BIL: HV winding 550 kV; LV winding 110 kV.; 2022 refurbishment and electrical-test report plus supplied nameplate drawing; no pre-refurbishment test records represented.; The supplied nameplate drawing states 138/13.8 kV; a voltage field in the 2022 test report states 115/13.8 kV. Obtain reconciliation and a matching current test package before technical acceptance.; Exterior photographs shown are from the 2022 refurbishment report. Request current dated photographs and inspect present condition through J&J.; Seller reports minimal previous service. J&J confirms it has not been installed since the 2022 refurbishment and has been maintained in storage. Earlier operating records are unavailable.; Documented exterior and cabinet cleaning/painting, bushings and LV bus bars, spare gaskets and bushing hardware; electrical testing included turns ratio, winding resistance, insulation resistance, power factor, excitation current and SFRA.; Inspection can be arranged with a 10% deposit, refundable only if the unit fails the buyer's tests or does not match the advertised specifications and condition. Confirm exact terms in the written offer.
Evidence reviewedProject-specific supplied approval drawings reviewed; final equipment OEM and serial identity require confirmationABB identified by the supplied replacement nameplate and historical refurbishment/test report; original OEM provenance to confirm
Technical value basisSupplied approval design drawings; a completed individual nameplate and final equipment identity have not been established.Supplied 2022 replacement nameplate and historical refurbishment/test report; current inspection is still required.
Details to confirmFinal OEM, individual equipment identity, manufacture year, tested impedance and factory reports; Final drawings, current preservation, complete accessories and shipping configurationConfirm the original OEM plate and vector clock; reconcile inconsistent voltage text in the historical test templates; Current inspection and oil analysis, complete earlier service history, accessories and final handling/shipping dimensions
Represented conditionBrand new, never used and never energized; 2024 approval drawings reviewed; serial identity requires confirmationReconditioned used transformer; refurbishment completed in 2022
Equipment locationUSALocation confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; approval drawings reviewed; unit identity requires documentation; subject to prior sale and written confirmationOffered by J&J; seller indicated 6-8 weeks for preparation/delivery on October 1, 2026. Current inspection, loading and delivery schedule by written confirmation.
Availability last confirmed2026-09-24Request current confirmation
Shipping estimateRequest a written dispatch and delivery schedule6–8 weeks quoted October 1, 2026; current preparation, loading and delivery schedule to confirm
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedYes — request matching unit drawingsNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist