Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare50 MVA-Class 138/13.8 kV Substation PackageJJ-TX-007120 MVA 138/34.5 kV Georgia Solar GSUJJ-TX-004
ManufacturerManufacturer to confirmGeorgia Transformer
Rating / output30/39.9/50 MVA at 55 C; 33.6/44.7/56 MVA at 65 C72/96/120 MVA; 25.2/33.6/42 MVA tertiary
Voltage / winding arrangement138 kV delta / 13.8 kV grounded wye138/34.5 kV with 12 kV buried-delta tertiary
Vector groupDelta–Grounded Wye; clock to confirmYNyn0+d1
Frequency60 Hz60 Hz
CoolingONAN / ONAF / ONAFONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JMeasured H–X: 6.93% at 72 MVA; design value 7.2%
Tap changerFive-position HV DETC: 131.1, 134.55, 138, 141.45 and 144.9 kV (±5%, 2.5% steps)HV OLTC; 117.3–158.7 kV (±15%); confirm the final switch and step schedule
Insulation / BILHV 650 kV; LV 110 kV, drawing basisHV line 650 kV; HV neutral, LV line and LV neutral 200 kV
Quantity represented1 represented design package1 documented unit
Technical details / open itemsOil-immersed substation transformer; ONAN/ONAF/ONAF, 60 Hz, three-phase; HV de-energized tap range: 131.1-144.9 kV; Final impedance, serial number, test data, and manufacture date are not populatedSolar GSU design; ONAN/ONAF1/ONAF2, 60 Hz, three-phase; Vector group YNyn0+d1 with HV OLTC and conservator oil system; Nameplate rating is used; an outline-drawing discrepancy requires final seller confirmation
Evidence reviewedProject-specific supplied approval drawings reviewed; final equipment OEM and serial identity require confirmationSerial-specific nameplate and approval drawings reviewed
Technical value basisSupplied approval design drawings; a completed individual nameplate and final equipment identity have not been established.Supplied unit nameplate; the nameplate takes precedence over the differing outline-drawing rating.
Details to confirmFinal OEM, individual equipment identity, manufacture year, tested impedance and factory reports; Final drawings, current preservation, complete accessories and shipping configurationResolve the outline-drawing rating discrepancy and confirm the final drawing revision; Current preservation, complete tests, dimensions and included accessory schedule
Represented conditionBrand new, never used and never energized; 2024 approval drawings reviewed; serial identity requires confirmationBrand new, never used and never energized; approval drawings reviewed
Equipment locationUSAUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; approval drawings reviewed; unit identity requires documentation; subject to prior sale and written confirmationAvailable; engineering package reviewed; subject to prior sale and written reconfirmation
Availability last confirmed2026-09-242026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedYes — request matching unit drawingsYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist