Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare50 MVA-Class 138/13.8 kV Substation PackageJJ-TX-007Five 110 MVA 138/34.5 kV Kolektor ETRA GSUsJJ-138-110-5
ManufacturerManufacturer to confirmKolektor ETRA
Rating / output30/39.9/50 MVA at 55 C; 33.6/44.7/56 MVA at 65 C66/88/110 MVA; 22/29.333/36.666 MVA tertiary
Voltage / winding arrangement138 kV delta / 13.8 kV grounded wye138/34.5 kV with 13.8 kV tertiary
Vector groupDelta–Grounded Wye; clock to confirmYNyn0+d11
Frequency60 Hz60 Hz
CoolingONAN / ONAF / ONAFONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JReviewed nameplate H–X: 8.09% at 66 MVA; supplied FAT reports 13.41% at 110 MVA. Match the test and plate to the selected unit.
Tap changerFive-position HV DETC: 131.1, 134.55, 138, 141.45 and 144.9 kV (±5%, 2.5% steps)HV OLTC; 124.2–151.8 kV (±10%); 16 raise / 16 lower steps of 0.625% on the reviewed plate
Insulation / BILHV 650 kV; LV 110 kV, drawing basisNot documented; confirm with J&J
Quantity represented1 represented design package5 units; matching unit packages available on request
Technical details / open itemsOil-immersed substation transformer; ONAN/ONAF/ONAF, 60 Hz, three-phase; HV de-energized tap range: 131.1-144.9 kV; Final impedance, serial number, test data, and manufacture date are not populatedGSU duty; ONAN/ONAF1/ONAF2, 60 Hz, three-phase, vector group YNyn0+d11; Measured impedance: 13.41% on a 110 MVA base at nominal tap; 2020 factory tests passed; those records do not establish current condition; Five-unit lot includes two 2020 builds and three 2021 builds; request all five serial-specific packages before quotation
Evidence reviewedProject-specific supplied approval drawings reviewed; final equipment OEM and serial identity require confirmationFive-unit opportunity confirmed by seller; rating plate and FAT package reviewed for one unit
Technical value basisSupplied approval design drawings; a completed individual nameplate and final equipment identity have not been established.One supplied nameplate and one factory-test package; values are not established for all five units.
Details to confirmFinal OEM, individual equipment identity, manufacture year, tested impedance and factory reports; Final drawings, current preservation, complete accessories and shipping configurationAll five matching nameplates, insulation levels, approved drawings and factory tests; Reconcile unit-specific impedance bases; confirm current preservation and individual shipping weights
Represented conditionBrand new, never used and never energized; 2024 approval drawings reviewed; serial identity requires confirmationBrand new, never used and never energized; 2020 factory records reviewed for one unit
Equipment locationUSAInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; approval drawings reviewed; unit identity requires documentation; subject to prior sale and written confirmationAvailable; 5 units represented; remaining unit packages require review; subject to prior sale and written confirmation
Availability last confirmed2026-09-242026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedYes — request matching unit drawingsNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist