Compare120 MVA 138/34.5 kV Georgia Solar GSUJJ-TX-00442 MVA 138/34.5 kV Virginia TransformerJJ-TX-102
ManufacturerGeorgia TransformerVirginia Transformer
Rating / output72/96/120 MVA; 25.2/33.6/42 MVA tertiary25.2/33.6/42 MVA
Voltage / winding arrangement138/34.5 kV with 12 kV buried-delta tertiary138/34.5 kV
Vector groupYNyn0+d1Winding connections and phase shift to confirm
Frequency60 HzNot documented; confirm with J&J
CoolingONAN / ONAF1 / ONAF2Not documented; confirm with J&J
Impedance and baseMeasured H–X: 6.93% at 72 MVA; design value 7.2%Not documented; confirm with J&J
Tap changerHV OLTC; 117.3–158.7 kV (±15%); confirm the final switch and step scheduleNot documented; confirm with J&J
Insulation / BILHV line 650 kV; HV neutral, LV line and LV neutral 200 kVNot documented; confirm with J&J
Quantity represented1 documented unit1 schedule entry; individual identity to confirm
Technical details / open itemsSolar GSU design; ONAN/ONAF1/ONAF2, 60 Hz, three-phase; Vector group YNyn0+d1 with HV OLTC and conservator oil system; Nameplate rating is used; an outline-drawing discrepancy requires final seller confirmationRatings and manufacturer are transcribed from the J&J-submitted schedule; verify them against the matching nameplate and current technical package.; Service history, present condition, frequency, winding arrangement, impedance, tap changer and accessories require unit-specific confirmation.; Historical schedule dates do not establish current dispatch timing, manufacture year or transferable warranty. Request present release terms and any applicable warranty in writing.
Evidence reviewedSerial-specific nameplate and approval drawings reviewedJ&J-submitted inventory schedule; matching unit-specific technical records to confirm
Technical value basisSupplied unit nameplate; the nameplate takes precedence over the differing outline-drawing rating.Submitted inventory schedule; manufacturer and electrical rating are representations, not an individual nameplate match.
Details to confirmResolve the outline-drawing rating discrepancy and confirm the final drawing revision; Current preservation, complete tests, dimensions and included accessory scheduleIndividual identity and quantity, current photos, condition/service history and preservation; Frequency, cooling/rise, winding connections and clock, impedance/base, BIL, conductor/fluid and tap schedule; Factory/current tests, included accessories, dimensions/weights and final release/transport scope
Represented conditionBrand new, never used and never energized; approval drawings reviewedCondition and service history require confirmation
Equipment locationUSALocation confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable; engineering package reviewed; subject to prior sale and written reconfirmationListed for inquiry by J&J; current allocation and release timing require written confirmation
Availability last confirmed2026-09-24Request current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageNot recorded as reviewed; request it
Drawings reviewedYes — request matching unit drawingsNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist