Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare300 MVA 138/34.5 kV Georgia TransformerJJ-TX-001120 MVA 138/34.5 kV Georgia Solar GSUJJ-TX-004
ManufacturerGeorgia TransformerGeorgia Transformer
Rating / output180/240/300 MVA; 63/84/105 MVA tertiary72/96/120 MVA; 25.2/33.6/42 MVA tertiary
Voltage / winding arrangement138/34.5 kV with 12 kV buried-delta tertiary138/34.5 kV with 12 kV buried-delta tertiary
Vector groupYNyn0+d1YNyn0+d1
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JMeasured H–X: 6.93% at 72 MVA; design value 7.2%
Tap changerNot documented; confirm with J&JHV OLTC; 117.3–158.7 kV (±15%); confirm the final switch and step schedule
Insulation / BILNot documented; confirm with J&JHV line 650 kV; HV neutral, LV line and LV neutral 200 kV
Quantity represented1 documented unit1 documented unit
Technical details / open itemsONAN/ONAF/ONAF, 60 Hz, three-phase, vector group YNyn0+d1; Measured 138/34.5 kV impedance: 9.67% on a 180 MVA base; Copper windings, conservator system, Type II mineral oil, and HV OLTCSolar GSU design; ONAN/ONAF1/ONAF2, 60 Hz, three-phase; Vector group YNyn0+d1 with HV OLTC and conservator oil system; Nameplate rating is used; an outline-drawing discrepancy requires final seller confirmation
Evidence reviewedSerial-specific nameplate reviewedSerial-specific nameplate and approval drawings reviewed
Technical value basisSerial-specific nameplate reviewedSupplied unit nameplate; the nameplate takes precedence over the differing outline-drawing rating.
Details to confirmMatching technical records, current condition, complete equipment scope and transport detailsResolve the outline-drawing rating discrepancy and confirm the final drawing revision; Current preservation, complete tests, dimensions and included accessory schedule
Represented conditionBrand new, never used and never energized; 2020 nameplate reviewedBrand new, never used and never energized; approval drawings reviewed
Equipment locationUSAUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable for sale — confirmed by J&J October 8, 2026; quotation and release terms on requestAvailable; engineering package reviewed; subject to prior sale and written reconfirmation
Availability last confirmed2026-10-082026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist