Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare300 MVA 138/34.5 kV Georgia TransformerJJ-TX-001Five 110 MVA 138/34.5 kV Kolektor ETRA GSUsJJ-138-110-5
ManufacturerGeorgia TransformerKolektor ETRA
Rating / output180/240/300 MVA; 63/84/105 MVA tertiary66/88/110 MVA; 22/29.333/36.666 MVA tertiary
Voltage / winding arrangement138/34.5 kV with 12 kV buried-delta tertiary138/34.5 kV with 13.8 kV tertiary
Vector groupYNyn0+d1YNyn0+d11
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JReviewed nameplate H–X: 8.09% at 66 MVA; supplied FAT reports 13.41% at 110 MVA. Match the test and plate to the selected unit.
Tap changerNot documented; confirm with J&JHV OLTC; 124.2–151.8 kV (±10%); 16 raise / 16 lower steps of 0.625% on the reviewed plate
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented1 documented unit5 units; matching unit packages available on request
Technical details / open itemsONAN/ONAF/ONAF, 60 Hz, three-phase, vector group YNyn0+d1; Measured 138/34.5 kV impedance: 9.67% on a 180 MVA base; Copper windings, conservator system, Type II mineral oil, and HV OLTCGSU duty; ONAN/ONAF1/ONAF2, 60 Hz, three-phase, vector group YNyn0+d11; Measured impedance: 13.41% on a 110 MVA base at nominal tap; 2020 factory tests passed; those records do not establish current condition; Five-unit lot includes two 2020 builds and three 2021 builds; request all five serial-specific packages before quotation
Evidence reviewedSerial-specific nameplate reviewedFive-unit opportunity confirmed by seller; rating plate and FAT package reviewed for one unit
Technical value basisSerial-specific nameplate reviewedReviewed nameplate, factory-test package and original general/transport drawings cover individual units in the five-unit lot; verify the selected unit before using these values.
Details to confirmMatching technical records, current condition, complete equipment scope and transport detailsAll five matching nameplates, insulation levels, approved drawings and factory tests; Reconcile unit-specific impedance bases; confirm current preservation and individual shipping weights
Represented conditionBrand new, never used and never energized; 2020 nameplate reviewedBrand new, never used and never energized; 2020 factory records reviewed for one unit
Equipment locationUSAInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityAvailable for sale — confirmed by J&J October 8, 2026; quotation and release terms on requestAvailable; 5 units represented; remaining unit packages require review; subject to prior sale and written confirmation
Availability last confirmed2026-10-082026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedYes — request the unit packageYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit only Request more info Request more info

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist