Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
CompareILJIN 167 MVA 230/34.5 kV New / Unused TransformerJJ-ILJIN-230-167167 MVA 230/34.5 kV Fortune Electric TransformerJJ-FORTUNE-230-167
ManufacturerILJIN ElectricFortune Electric
Rating / output100/133/167 MVA100/133/167 MVA; 35 MVA tertiary
Voltage / winding arrangement230/34.5 kV; tertiary voltage to confirm230/34.5 kV with 13.3 kV buried-delta tertiary
Vector groupYNyn0+d represented; tertiary clock to confirmYNyn0d1
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JNot documented; confirm with J&J
Tap changerNot documented; confirm with J&JHV OLTC; 207–253 kV (±10%), design basis
Insulation / BILNot documented; confirm with J&JHV line 750 kV; HV neutral and LV 200 kV; tertiary 110 kV
Quantity represented1 represented unit1 unit
Technical details / open itemsThe individual August offer expressly identifies this ILJIN option as new/unused and never energized; that offer was forwarded again September 30, 2026.; A separate September 30 equipment table repeats 100/133/167 MVA and 230/34.5 kV. Dispatch location and allocation require current confirmation through J&J.; The supplied vector description is YNyn0+d. Obtain the individual nameplate, tertiary rating and voltage, vector clock, frequency, cooling stages and test records before duty approval.; Confirm preservation and storage history, actual warranty provider and transferable written coverage, loading and shipping terms with the quotation.; This ILJIN offer is distinct from the separately listed Fortune Electric 167 MVA transformer; no additional Fortune unit is implied.Three-phase, 60 Hz; ONAN/ONAF1/ONAF2 cooling; 65 C winding rise; Grounded-wye / grounded-wye / delta; vector group YNyn0d1; HV OLTC range 207-253 kV; 13.3 kV, 35 MVA buried-delta tertiary; Copper windings, Type II mineral oil; Nameplate drawing identifies suitability for step-up operation; final test results and impedance available subject to confirmation
Evidence reviewedIndividual written offer, repeated in a September 30 equipment listingNameplate drawing reviewed
Technical value basisReceived written equipment offer; individual technical records require review.Supplied design nameplate and outline drawings; blank final values remain unconfirmed.
Details to confirmIndividual nameplate, frequency, cooling/rise, tertiary duty and vector clock; Impedance/base, BIL, taps, copper/fluid specification, factory tests, preservation and transport scopeFinal tested impedance and base, manufacture year and final tap-switch specification; Final oil quantity, dimensions, tests, current preservation and complete accessories
Represented conditionNew / unused and never energized, as explicitly represented in the offerBrand new, never used and never energized
Equipment locationInternational; dispatch location confirmed with quotationUSA
Technical records reviewed2026-10-082026-10-08
AvailabilityListed in received September 30, 2026 offers; current allocation, condition and dispatch timing require written confirmationAvailable; subject to prior sale and written confirmation
Availability last confirmedRequest current confirmation2026-09-24
Shipping estimateRequest a written dispatch and delivery scheduleRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist