Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.
| Compare | Wärtsilä W16V32 HFO Generators — Six SetsJJ-GEN-008 | 70 CAT 3516B HD 1600 kW Diesel Generators — 50 HzJJ-GEN-001 |
|---|---|---|
| Manufacturer | Wärtsilä | Caterpillar |
| Rating / output | 7.68 MW engine rating; ABB alternator 9.1 MVA at 0.8 power factor per set; net electrical output to confirm | 1600 kWe / 2000 kVA continuous per unit |
| Voltage / winding arrangement | 11 kV | 400 V, three-phase |
| Vector group | ABB alternator Y connection on the reviewed nameplate; not a transformer vector group | Not applicable; generator connection to confirm |
| Frequency | 60 Hz | 50 Hz |
| Cooling | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Impedance and base | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Tap changer | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Insulation / BIL | Not documented; confirm with J&J | Not documented; confirm with J&J |
| Quantity represented | 6 offered sets | 70 offered units |
| Technical details / open items | Two original equipment photos from the October 5, 2026 offer are shown. Photo capture dates were not supplied; request a current inspection and preservation records.; W16V32 engine plates show 7680 kW at 720 RPM. The ABB alternator plate shows 9100 kVA at 11 kV, 60 Hz and 0.8 power factor, equivalent to 7.28 MW electrical nameplate duty before auxiliary loads and site derating.; Engine power, alternator capacity and guaranteed net electrical output are separate values. Aggregate output claims in the received package conflict; no unverified package MW total is published.; This six-set HFO offer is separate from the sixteen-set 50 Hz Wärtsilä 20V34SG natural-gas plant.; Confirm all six matching generator records, current allocation, preservation, auxiliaries, factory tests, warranty, dismantling/loading responsibilities and release schedule before purchase. | Reported engine speed: 1500 RPM.; Request the individual unit schedule, nameplates, service records and load-test results before selecting a fleet.; Continuous output is the offered rating; site conditions and auxiliary loads must be checked for net project output. |
| Evidence reviewed | Supplied engine and ABB alternator nameplates plus the written six-set offer; match records to each selected set | Written equipment offer; unit-specific technical records and identity to confirm |
| Technical value basis | Supplied W16V32 engine and ABB alternator nameplates for the written six-set offer; match each selected engine-generator set to its records. | Received equipment offer; ratings, history and scope are representations until matched to the selected package. |
| Details to confirm | All six matching alternator records, current allocation, actual hours/testing and preservation/inspection findings; Guaranteed net electrical output at project conditions; aggregate package output claims require reconciliation; Factory tests, warranty terms, exact auxiliary schedule, complete dimensions and shipping weights; Dismantling, loading, packing, transportation and release schedule | Matching engine/turbine and generator nameplates, individual hours/starts, maintenance/overhaul records and current tests; Electrical duty, site-output basis, fuel/emissions, complete auxiliaries and loading/dismantling/transport scope |
| Represented condition | New / unused and zero operating hours reported; current preservation and condition to confirm | Used; reported operating hours vary by unit |
| Equipment location | Location confirmed with quotation | Location confirmed with quotation |
| Technical records reviewed | 2026-10-08 | 2026-10-08 |
| Availability | Offered subject to prior sale; current availability and release schedule to confirm | Offered subject to prior sale; current availability and release schedule to confirm |
| Availability last confirmed | Request current confirmation | Request current confirmation |
| Shipping estimate | Request a written dispatch and delivery schedule | Request a written dispatch and delivery schedule |
| Nameplate reviewed | Yes — request the unit package | Not recorded as reviewed; request it |
| Drawings reviewed | Not recorded as reviewed; request them | Not recorded as reviewed; request them |
| Factory test report reviewed | Not recorded as reviewed; request test records | Not recorded as reviewed; request test records |
| This unit only | Request more info | Request more info |
One request
Request Availability for Your Shortlist.
Email Tommy to discuss these options. The listing IDs will already be in the email subject.
What still needs to be checked?
Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.
Match the nameplate to the specification · Review surplus equipment records · Procurement checklist