Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Turbine opportunity · JJ-TUR-009

Siemens SGT5-2000E Combined-Cycle Plant — Approx. 738 MW Gross

Equipment location: Location confirmed with quotation. J&J is based in Sugar Land, Texas and serves projects nationwide.

Condition: Unused; zero firing and never commissioned reported. J&J offers this Siemens turbine position for project screening. Three gas-turbine generators, three steam-turbine generators and three HRSGs; cooling/lubrication, gas/water treatment, transformers, central controls, HV/LV equipment, MCCs, fire systems, stacks, piping and offered auxiliaries; final schedule to confirm. The received offer is dated 2026-10-01; current allocation, price and delivery require written reconfirmation. Email Tommy with reference JJ-TUR-009 for specifications, price and current release timing. Listing information reviewed .

Availability & record date
Written equipment offerOffer received Request current allocation and release terms · subject to prior sale
Photos on requestAsk Tommy for photos & specs
Photo availability

Public photos are not shown for this listing. Ask J&J for a current photo set and the matching technical records.

Equipment summary

Specifications and scope

Unit IDJJ-TUR-009
ManufacturerSiemens
Manufacturer basisWritten equipment offer; unit-specific technical records and identity to confirm
Rating3 × 166 MW gas turbines + 3 × 80 MW steam turbines; approximately 738 MW gross
Voltage / output10.5 kV
Frequency50 Hz
FuelNatural gas
Manufacture / history dates2012 reported manufacture
Included package scopeThree gas-turbine generators, three steam-turbine generators and three HRSGs; cooling/lubrication, gas/water treatment, transformers, central controls, HV/LV equipment, MCCs, fire systems, stacks, piping and offered auxiliaries; final schedule to confirm
Received offer date
Quantity1 offered complete plant
AvailabilityOffered subject to prior sale; current availability and release schedule to confirm
Condition basisUnused; zero firing and never commissioned reported
Current locationLocation confirmed with quotation
Listing information reviewed

Technical values and record basis

Received equipment offer; ratings, history and scope are representations until matched to the selected package.

Plant configuration represented3 × 166 MW gas turbines + 3 × 80 MW steam turbine generators; approximately 738 MW gross, not guaranteed net site output
CombustionDLN represented
Preservation basisDedicated storage and some major components in original factory crates represented; current preservation/completeness to inspect

Details to confirm for this listing

  • Matching engine/turbine and generator nameplates, individual hours/starts, maintenance/overhaul records and current tests
  • Electrical duty, site-output basis, fuel/emissions, complete auxiliaries and loading/dismantling/transport scope

Technical highlights

  • Dry Low NOx combustion reported.
  • Gross plant output must be reconciled with auxiliary loads, site conditions and the actual offered equipment list.
  • Request preservation history, completion status, unit-specific records, dismantling scope and current release terms.

Evidence reviewed

Written equipment offer; unit-specific technical records and identity to confirm

Records apply only to the stated unit or design basis.

Availability and terms

Offered subject to prior sale; current availability and release schedule to confirm

Ask for the current technical package, price, included accessories and delivery terms.

Confirm the purchase and delivery scope

Ask J&J to confirm the proposed unit’s allocation, price, inspection access, included accessories, loading and freight boundary, receiving arrangements, release schedule, deposit or reservation terms and any applicable warranty. Photos, matching records and inspection arrangements are coordinated through J&J.

Request written terms

Check this package against your project

Compare electrical output, duty, frequency, fuel, site conditions, operating history and included equipment. Request matching nameplates, maintenance/overhaul records and test reports for the specific package.

How is availability confirmed for this package?

Offered subject to prior sale; current availability and release schedule to confirm. The received offer date and record review are not a current reservation. Ask J&J for written allocation, price and release timing.

What equipment is included?

Three gas-turbine generators, three steam-turbine generators and three HRSGs; cooling/lubrication, gas/water treatment, transformers, central controls, HV/LV equipment, MCCs, fire systems, stacks, piping and offered auxiliaries; final schedule to confirm. Confirm the complete equipment schedule, accessories, controls, loading, dismantling where applicable and shipment scope in the quotation.

How do I request the technical package?

Email tommy@jjtransformers.com with reference JJ-TUR-009, required MW, voltage, frequency, fuel, quantity and needed-on-site date, or call 346-276-9540.

Compare related equipment

Review gas and steam turbines

Need a different unit?

Send the exact requirement.

Include MVA or MW, voltage, quantity, site, and need-by date for a private match.

Email for Availability
Call Email Sales