Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare345/34.5 kV Transformer Production PositionsJJ-TX-204220 MVA 345/34.5 kV Prolec GE TransformerJJ-TX-002
ManufacturerManufacturer disclosed in the qualified technical packageProlec GE
Rating / output266 MVA offered; final rating requires reconciliation132/176/220 MVA; 46.2/61.6/77 MVA tertiary
Voltage / winding arrangement345 kV HV / 34.5 kV LV345/34.5 kV with 13.8 kV delta tertiary
Vector groupRequires confirmationGrounded Wye–Wye / Delta; clock to confirm
Frequency60 Hz60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF / ONAF
Impedance and baseNot documented; confirm with J&JDesign H–X: 12.0% at 132 MVA
Tap changerNot documented; confirm with J&JNot documented; confirm with J&J
Insulation / BILNot documented; confirm with J&JNot documented; confirm with J&J
Quantity represented2 offered positions1 documented unit
Technical details / open itemsSeller offer summary; exact cooling stages require confirmation.; Ask J&J for the included U.S.-port shipping, commissioning and manufacturer warranty scope in the written offer.; Modifications can be reviewed before completion; feasibility, cost and schedule impact require OEM confirmation.; Any warranty provider, scope, transfer eligibility, start date and commissioning boundary must appear in the written quotation.; The offered summary states 266 MVA. Supplied outlines include different 226 MVA and 266 MVA designs without a confirmed match to each position. Resolve the individual nameplate and design before technical acceptance.Collector step-up duty; ONAN/ONAF/ONAF, 60 Hz, three-phase; Grounded-wye / grounded-wye / delta winding configuration; Nominal design H-X impedance: 12.0% on a 132 MVA base
Evidence reviewedSeller offer summary; exact cooling stages require confirmationSerial-specific nameplate and approval drawings reviewed
Technical value basisReceived production offer and existing reviewed design package; final individual nameplates and factory tests remain pending.Supplied nameplate and approval drawings; design values require matching final factory records.
Details to confirmMatch the final design/rating and drawing revision to each offered manufacturing position; Final frequency, cooling/rise, winding duty, impedance/base, BIL, taps, accessories and transport dimensions/weightsFinal tested impedance, insulation levels, complete tap schedule and approved drawing revision; Overall and shipping dimensions, shipping weight, accessory schedule and current preservation
Represented conditionFactory manufacturing position; completion pendingBrand new, never used and never energized; approval drawings reviewed
Equipment locationDispatch location confirmed with quotationUSA
Technical records reviewed2026-10-082026-10-08
Availability2027 manufacturing positions offered for allocation; current release terms require written confirmationAvailable; nameplate and approval drawings reviewed; subject to prior sale and written confirmation
Availability last confirmedRequest current confirmation2026-09-24
Shipping estimateProjected 2027 completion; shipment and receiving dates require written confirmationRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales