Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare208 MVA 115/34.5 kV Transformer — 2027JJ-TX-20295 MVA 115/34.5 kV Virginia TransformerJJ-TX-101
ManufacturerManufacturer disclosed in the qualified technical packageVirginia Transformer
Rating / output124.8/166.4/208 MVA57/76/95 MVA
Voltage / winding arrangement115 kV HV / 34.5 kV LV115/34.5 kV
Vector groupGrounded wye / grounded wyeWinding connections and phase shift to confirm
Frequency60 HzNot documented; confirm with J&J
CoolingONAN / ONAF1 / ONAF2Not documented; confirm with J&J
Impedance and baseH–X 9% at 125 MVA (supplied design sheet)Not documented; confirm with J&J
Tap changerHV OLTC ±8 × 1.25% (±10%); no taps shown on X or Y windingsNot documented; confirm with J&J
Insulation / BILHV line 550 kV; HV neutral, LV line and LV neutral 200 kVNot documented; confirm with J&J
Quantity represented1 offered position2 schedule entries; distinct unit identities to confirm
Technical details / open itemsSupplied design data sheet; final unit-specific nameplate and FAT pending.; Ask J&J for the included U.S.-port shipping, commissioning and manufacturer warranty scope in the written offer.; Modifications can be reviewed before completion; feasibility, cost and schedule impact require OEM confirmation.; Any warranty provider, scope, transfer eligibility, start date and commissioning boundary must appear in the written quotation.; Design basis: ONAN/ONAF1/ONAF2, 60 Hz, 65 C temperature rise; grounded-wye high and low sides.; HV OLTC design range ±10%; preliminary 13.8 kV open-delta tertiary. Final unit-specific configuration requires approval.; Design H-X impedance: 9% at a 125 MVA base. This is a design-sheet value, not a final tested result.Ratings and manufacturer are transcribed from the J&J-submitted schedule; verify them against the matching nameplate and current technical package.; Service history, present condition, frequency, winding arrangement, impedance, tap changer and accessories require unit-specific confirmation.; Historical schedule dates do not establish current dispatch timing, manufacture year or transferable warranty. Request present release terms and any applicable warranty in writing.; Repeated schedule entries are grouped here; quantity is not represented as independently verified stock.
Evidence reviewedSupplied design data sheet; final unit-specific nameplate and FAT pendingJ&J-submitted inventory schedule; matching unit-specific technical records to confirm
Technical value basisSupplied guaranteed design sheet; these are design values, not final tested values for an individually matched unit.Submitted inventory schedule; manufacturer and electrical rating are representations, not an individual nameplate match.
Details to confirmFinal unit-specific nameplate, approved revision, tested impedance/losses and final tertiary arrangement; Conductor, OLTC switch specification, complete accessories, current photos and preservation or manufacturing progressIndividual identity and quantity, current photos, condition/service history and preservation; Frequency, cooling/rise, winding connections and clock, impedance/base, BIL, conductor/fluid and tap schedule; Factory/current tests, included accessories, dimensions/weights and final release/transport scope
Represented conditionFactory manufacturing position; completion pendingCondition and service history require confirmation
Equipment locationDispatch location confirmed with quotationLocation confirmed with quotation
Technical records reviewed2026-10-082026-10-08
Availability2027 manufacturing positions offered for allocation; current release terms require written confirmationListed for inquiry by J&J; current allocation and release timing require written confirmation
Availability last confirmedRequest current confirmationRequest current confirmation
Shipping estimateProjected 2027 completion; shipment and receiving dates require written confirmationRequest a written dispatch and delivery schedule
Nameplate reviewedNot recorded as reviewed; request itNot recorded as reviewed; request it
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist