Company base: Sugar Land, Texas · Nationwide sales · Tommy Marco

346-276-9540 tommy@jjtransformers.com

Your equipment shortlist

Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare26.7 MVA 46/12.47 kV Virginia TransformerJJ-TX-104Royal SMIT 525/69 kV Transformers — 3 AvailableJJ-SMIT-525-3
ManufacturerVirginia TransformerRoyal SMIT
Rating / output16/21.3/26.7 MVA240/320/400 MVA; 250 MVA maximum step-down; 90 MVA tertiary
Voltage / winding arrangement46/12.47 kV525/69 kV with 13.7 kV buried-delta tertiary
Vector groupWinding connections and phase shift to confirmYNyn0(d1) — Wye–Wye / buried Delta
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF / ONAF
Impedance and baseNot documented; confirm with J&JH–X: 12.90% at 240 MVA, 525/69 kV, 85°C
Tap changerNot documented; confirm with J&JHV OLTC; 472.5–577.5 kV (±10%); 16 raise / 16 lower steps of 0.625%
Insulation / BILNot documented; confirm with J&JHV winding 1550 kV / bushing 1675 kV; LV 350 kV; tertiary 150 kV
Quantity represented1 schedule entry; individual identity to confirm3 units
Technical details / open itemsRatings and manufacturer are transcribed from the J&J-submitted schedule; verify them against the matching nameplate and current technical package.; Service history, present condition, frequency, winding arrangement, impedance, tap changer and accessories require unit-specific confirmation.; Historical schedule dates do not establish current dispatch timing, manufacture year or transferable warranty. Request present release terms and any applicable warranty in writing.Three units offered for allocation; availability and 4–8 week shipping schedule confirmed by J&J on October 1, 2026.; Nameplate rating: 240/320/400 MVA with ONAN/ONAF/ONAF cooling. Maximum stated duty: 400 MVA step-up or 250 MVA step-down.; Three-phase, 60 Hz; 525 kV grounded-wye high side, 69 kV wye low side, and 13.7 kV buried-delta tertiary rated 90 MVA.; Copper windings; MR on-load tap changer; HV tap range 472.5–577.5 kV (±10%).; HV BIL: 1550 kV winding / 1675 kV bushing. LV BIL: 350 kV.; Nameplate H-X impedance: 12.90% at 240 MVA base, 525/69 kV, 85°C.; Supplied 2022 factory acceptance test report records Passed for the documented unit. Nameplate, outline drawing and test report available through J&J; match the records to all three units before purchase.
Evidence reviewedJ&J-submitted inventory schedule; matching unit-specific technical records to confirmSupplied nameplate, outline drawing and factory acceptance test report
Technical value basisSubmitted inventory schedule; manufacturer and electrical rating are representations, not an individual nameplate match.Supplied nameplate for one documented unit; match the complete package to each of the three offered units.
Details to confirmIndividual identity and quantity, current photos, condition/service history and preservation; Frequency, cooling/rise, winding connections and clock, impedance/base, BIL, conductor/fluid and tap schedule; Factory/current tests, included accessories, dimensions/weights and final release/transport scopeMatching records for each offered unit, current condition, included accessories and transport scope; Unit-specific factory tests, present preservation and the step-down duty limit
Represented conditionCondition and service history require confirmation2022 manufacture shown in supplied nameplate; condition and service history confirmed with quotation
Equipment locationLocation confirmed with quotationInternational; dispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityListed for inquiry by J&J; current allocation and release timing require written confirmationImmediately available; estimated 4–8 weeks to ship; subject to prior sale
Availability last confirmedRequest current confirmation2026-10-01
Shipping estimateRequest a written dispatch and delivery schedule4–8 weeks to ship
Nameplate reviewedNot recorded as reviewed; request itYes — request the unit package
Drawings reviewedNot recorded as reviewed; request themYes — request matching unit drawings
Factory test report reviewedNot recorded as reviewed; request test recordsReport reviewed; confirm matching records for each unit
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.

Match the nameplate to the specification · Review surplus equipment records · Procurement checklist

Call Email Sales