Compare equipment before you request it.

Review the published facts side by side. Matching a voltage or MVA rating does not establish compatibility. Ask your project engineer to review the complete unit records.

J&J Transformers LLC · 346-276-9540 · tommy@jjtransformers.com

Published specifications for 2 alternatives. Availability remains subject to prior sale and written reconfirmation.
Compare42 MVA 138/34.5 kV Virginia TransformerJJ-TX-102208 MVA 138/34.5 kV Stored Surplus TransformerJJ-TX-201
ManufacturerVirginia TransformerManufacturer disclosed in the qualified technical package
Rating / output25.2/33.6/42 MVA125/166/208 MVA
Voltage / winding arrangement138/34.5 kV138 kV HV / 34.5 kV LV
Vector groupWinding connections and phase shift to confirmGrounded wye / grounded wye
FrequencyNot documented; confirm with J&J60 Hz
CoolingNot documented; confirm with J&JONAN / ONAF1 / ONAF2
Impedance and baseNot documented; confirm with J&JH–X 9% at 125 MVA (supplied design sheet)
Tap changerNot documented; confirm with J&JHV OLTC ±8 × 1.25% (±10%); no taps shown on X or Y windings
Insulation / BILNot documented; confirm with J&JHV line 650 kV; HV neutral, LV line and LV neutral 200 kV
Quantity represented1 schedule entry; individual identity to confirm1 offered position
Technical details / open itemsRatings and manufacturer are transcribed from the J&J-submitted schedule; verify them against the matching nameplate and current technical package.; Service history, present condition, frequency, winding arrangement, impedance, tap changer and accessories require unit-specific confirmation.; Historical schedule dates do not establish current dispatch timing, manufacture year or transferable warranty. Request present release terms and any applicable warranty in writing.Supplied design data sheet; final unit-specific nameplate and FAT pending.; Ask J&J for the included U.S.-port shipping, commissioning and manufacturer warranty scope in the written offer.; Technical suitability subject to buyer review; Any warranty provider, scope, transfer eligibility, start date and commissioning boundary must appear in the written quotation.; Design basis: ONAN/ONAF1/ONAF2, 60 Hz, 65 C temperature rise; grounded-wye high and low sides.; HV OLTC design range ±10%; preliminary 13.8 kV open-delta tertiary. Final unit-specific configuration requires approval.; Design H-X impedance: 9% at a 125 MVA base. This is a design-sheet value, not a final tested result.
Evidence reviewedJ&J-submitted inventory schedule; matching unit-specific technical records to confirmSupplied design data sheet; final unit-specific nameplate and FAT pending
Technical value basisSubmitted inventory schedule; manufacturer and electrical rating are representations, not an individual nameplate match.Supplied guaranteed design sheet; these are design values, not final tested values for an individually matched unit.
Details to confirmIndividual identity and quantity, current photos, condition/service history and preservation; Frequency, cooling/rise, winding connections and clock, impedance/base, BIL, conductor/fluid and tap schedule; Factory/current tests, included accessories, dimensions/weights and final release/transport scopeFinal unit-specific nameplate, approved revision, tested impedance/losses and final tertiary arrangement; Conductor, OLTC switch specification, complete accessories, current photos and preservation or manufacturing progress
Represented conditionCondition and service history require confirmationSurplus in storage; service history requires confirmation
Equipment locationLocation confirmed with quotationDispatch location confirmed with quotation
Technical records reviewed2026-10-082026-10-08
AvailabilityListed for inquiry by J&J; current allocation and release timing require written confirmationStored surplus offered for allocation; current release terms require written confirmation
Availability last confirmedRequest current confirmationRequest current confirmation
Shipping estimateRequest a written dispatch and delivery scheduleRelease, loading and shipping dates confirmed with quotation
Nameplate reviewedNot recorded as reviewed; request itNot recorded as reviewed; request it
Drawings reviewedNot recorded as reviewed; request themNot recorded as reviewed; request them
Factory test report reviewedNot recorded as reviewed; request test recordsNot recorded as reviewed; request test records
This unit onlyEmail for specs & price Email for specs & price

One request

Request Availability for Your Shortlist.

Email Tommy to discuss these options. The listing IDs will already be in the email subject.

Email this shortlist

What still needs to be checked?

Confirm frequency, cooling-stage ratings, impedance and its base, taps, vector group, grounding, BIL, site conditions and included scope against the project specification. A table cannot approve the fit.